Australian Pipeline Valve - Installation, Operation and Maintenance Manual
13
API6D THROUGH CONDUIT EXPANDING GATE VALVE - AP400-405 SERIES
5 . 0 V A LV E D I S A S S E M B LY
The following should only be performed by an APV approved reconditioner.
Note, The below parts refer to the general drawing labelled Diagram 1. This is a general overview
drawing only. Each size & class range does vary so refer to the actual as-built drawing.
6 . 0 I N S P E C T I O N A N D R E P A I R S
The following inspection and maintenance procedures of valve components should be performed by a
professional valve repairer. Replace any parts that are damaged with genuine APV spare parts.
The sampled diagram labelled Diagram 1 only shows the main parts. The Bill of Material varies according
to size, class & trim, hence refer to as-built drawing.
6.1 BOLTS, NUTS AND THREADED COMPONENTS
a- All bolts, nuts, and threaded particulars shall be cleaned with kerosene, dried and lubricated with
protective oil. The body bolts should have a copper based anti-seize grease applied. To ensure grease
does not dry or wash out and does prevent corrosion protective plastic nut caps with grease nipples
are available.
b- The threads should be visually inspected to verify the integrity of the components.
If a gasket or seal is disturbed while removing or adjusting soft parts, APV
recommends installing a new gasket or seal. A proper seal is required to ensure
optimum operation.
Check the stem sealing area for pressurised process fluids even after the valve has
been removed from the pipeline, particularly when removing packing hardware or
sealing rings.