Emptying the Appliance

GL346-A/GL347-A/GL348-A/GL349-A

HF150-A/HF151-A/HF152-A/HF153-A

Drain the appliance by using the tap to empty

Drain the appliance with hand over the hand sensor 

until empty

Cleaning, Care & Maintenance

• 

Always turn off and disconnect the appliance from the power supply before cleaning.

•  Use soapy water and a damp cloth to clean the exterior of the appliance.

•  Dry thoroughly after cleaning.

De-scaling

For the best water quality, Apuro recommend that a water filter is installed to the mains water supply, 

particularly in hard water areas. Doing so will reduce the build up of limescale and contaminants in the 

water tank thus maintaining energy efficiency and prolonging the life of the appliance. 

To de-scale the appliance:

1.  Pour a solution of de-scaler and water into the appliance.

2.  Brush the interior gently with a soft bristled brush.

3.  Discard the solution collected in the jug.

4.  Fill the appliance with clean water and turn back On to flush out the system. Flush out the system 

thoroughly to remove any de-scaler residue.

5.  The appliance is now ready for use. 

Note: Use a suitable de-scaler and always follow the instructions on the 

container.
Apuro recommend that this appliance is de-scaled every 3 months or more 

frequently in hard water areas.
IMPORTANT: Failure to de-scale or maintain will invalidate your guarantee.

Troubleshooting

Fault

Probable Cause

Solution

The unit is not working

The unit is not switched on

Check the unit is plugged in correctly and 

switched on

Plug or lead is damaged

Call Apuro agent or qualified Technician

Power supply

Check power supply

Thermal fuse has activated

Reset Thermal fuse (see page 4)

Power light comes on 

but water does not 

reach temperature

Thermostat fault

Call Apuro agent or qualified technician

The tap is leaking

The tap has become loose

Tighten the tap handle

The tap is leaking (for 

GL346-A series)

The tap has become loose

Tighten the tap handle

Water not dispensing 

(for HF150-A series)

Sensor not detecting the cup

Not suited for glass cups, so ensure the cup 

used is opaque

GL346-A to GL349-A_HF150-A to HF153-A_A5_v6_20211123.indb   5

GL346-A to GL349-A_HF150-A to HF153-A_A5_v6_20211123.indb   5

2021/11/23   10:35

2021/11/23   10:35

Содержание GL346-A

Страница 1: ...A GL349 A HF150 A HF151 A HF152 A HF153 A Water Boiler Instruction manual GL346 A to GL349 A_HF150 A to HF153 A_A5_v6_20211123 indb 1 GL346 A to GL349 A_HF150 A to HF153 A_A5_v6_20211123 indb 1 2021 1...

Страница 2: ...DO NOT touch the outer surfaces of the appliance They become hot during use Suitable for indoor use only Always switch off and disconnect the power supply to the appliance when not in use Keep all pac...

Страница 3: ...iance from the packaging Make sure that all protective plastic film and plastic coatings are thoroughly removed from all surfaces Note Before using for the first time clean the interior of the applian...

Страница 4: ...cally cut power The Safety Cut out switch is located on the underside of the appliance To reset the appliance 1 Empty the appliance and allow to cool 2 Press the reset button until it clicks WARNING E...

Страница 5: ...sh out the system thoroughly to remove any de scaler residue 5 The appliance is now ready for use Note Use a suitable de scaler and always follow the instructions on the container Apuro recommend that...

Страница 6: ...dily accessible Compliance The product must not be disposed of as household waste To help prevent possible harm to human health and or the environment the product must be disposed of in an approved an...

Страница 7: ...specificeerde uitrusting goedgekeurd is volgens de bovenstaande Richtlijn en en Standaard en Je soussign confirme la conformit de l quipement cit dans la pr sente la aux Directive s et Norme s ci dess...

Страница 8: ...46 A to GL349 A_HF150 A to HF153 A_A5_v6_20211123 GL346 A to GL349 A_HF150 A to HF153 A_A5_v6_20211123 indb 8 GL346 A to GL349 A_HF150 A to HF153 A_A5_v6_20211123 indb 8 2021 11 23 10 35 2021 11 23 10...

Отзывы: