4
AU
Telephone Helpline: 1300225960
Fitting head unit to the Fryer body
1. Position the head unit onto the body of the fryer,
locating it into the hole (A) at the side of the main
body by the pin (B) on the side of the head unit.
2. Rotate the head unit and put spring pin (C) into
the hole (D) ,then it can hold the position if the
appliance is not going to be used.
3. Continue to push spring pin (C) and rotate the head
unit, the element is lowered into the pan and the
head unit is close to the operating position.
4. When the spring pin is put into the hole (E), the
safety switch (F) will work and the appliance will
work.
The fryer can now be filled with the appropriate cooking
oil.
Connect the Fryer to the correct power supply and it is
ready to operate.
Operation
1. Please ensure Oil level is between Min and Max lines.
2. Turn on the power switch. Then turn the thermostat dial to the required temperature setting.
3. Allow time for the oil temperature to reach the required setting. While the oil is heating, the green
light will be on. When the oil has reached the required temperature, the green light will switch off.
4. As the oil temperature fluctuates, the thermostat will operate to maintain the set temperature, the
indicator light will be lit when the Fryer is heating the oil.
5. A temperature setting of between 170°C and 180°C will be sufficient for most cooking. However this
may vary for particular food types or according to individual requirements.
Using the timer
The digital timer with audible alarm can be set from 1 second to 15 minutes. The timer provides an
audible alarm only; after the set time expires unit will continue to operate at set temperature.
•
START/STOP:
Press START/STOP to start timer, press again
to stop. The timer will provide an audible alarm after the
set time. The alarm will beep 10 times and the display will
continue to flash until timer is reset (press the START/STOP
button).
•
UP:
Press UP to add extra time.
•
DOWN:
Press DOWN to reduce time.
•
PROGRAM:
There are a total of 6 programmable timer settings. The default factory program settings
are given below.
Program
1
2
3
4
5
6
Factory preset time
00:30 01:00 01:30 02:00 02:30 03:00
• To change the length of a program select the program you want to change by scrolling using the
PROGRAM button.
• Adjust the program time by using the UP and DOWN buttons. Press START/STOP to commence the
count-down. The new program time will be automatically stored.
• If the unit is left without power for more than 24hrs the timer settings will revert to the factory
defaults.
FC374-A to FC377-A_A5_v2_20210715.indb 4
FC374-A to FC377-A_A5_v2_20210715.indb 4
2021/7/15 11:49
2021/7/15 11:49