background image

 

 

Table of Contents 

 

1. Introduction ................................................................................................................................................... 1

 

2. Important Safety Warning (SAVE THESE INSTRUCTIONS) ...................................................................... 1

 

3. Product Overview ......................................................................................................................................... 2

 

4. Installation ..................................................................................................................................................... 2

 

5. Operation ....................................................................................................................................................... 5

 

6. Trouble Shooting ........................................................................................................................................ 12

 

7. Specifications ............................................................................................................................................. 13

 

Содержание Inverex S1200 XP Solar

Страница 1: ...Model No S1200 XP Solar S2400 XP Solar 720W 1440W V 1 0 Quick Guide...

Страница 2: ...Table of Contents 1 Introduction 1 2 Important Safety Warning SAVE THESE INSTRUCTIONS 1 3 Product Overview 2 4 Installation 2 5 Operation 5 6 Trouble Shooting 12 7 Specifications 13...

Страница 3: ...ualified service center when service or repair is required WARNING Provide ventilation to outdoors from the battery compartment The battery enclosure should be designed to prevent accumulation and con...

Страница 4: ...ry terminal RED cable to the positive terminal BLACK cable to the negative terminal WARNING Please use the appropriate battery cable Please refer to Important Safety Warnings Section for the details S...

Страница 5: ...rnal battery terminals Step 8 Take the DC breaker on Connect to Solar Panel CAUTION Before connecting to PV modules please install separately a DC circuit breaker between inverter and PV modules WARNI...

Страница 6: ...PV module numbers in parallel Take S1200 inverter as an example to select proper PV modules After considering Voc of PV module not exceeds 40Vdc and max Vmpp of PV module close to 15Vdc or within 15Vd...

Страница 7: ...down BAT MODE Buzzing continuously Line mode LCD Display Display Function Input source information Indicates the AC input Indicates the PV input Indicate input voltage input frequency battery voltage...

Страница 8: ...ng mode Press UP or DOWN button to select setting programs And then press ENTER button to confirm the selection or ESC button to exit Setting Programs Program Description Selectable option 00 Exit set...

Страница 9: ...ge Wide default If selected acceptable AC input voltage range will be within 90 280VAC Narrow If selected acceptable AC input voltage range will be within 170 280VAC 06 Auto restart when overload occu...

Страница 10: ...t priority Utility will charge battery only when solar energy is not available Utility first Utility will charge battery as first priority Solar energy will charge battery only when utility power is n...

Страница 11: ...uency PV voltage charging current battery voltage output voltage output frequency load percentage load in Watt load in VA load in Watt DC discharging current main CPU Version and second CPU Version Se...

Страница 12: ...PU version checking Secondary CPU version 00003 03 Output frequency Output frequency 50Hz Operating Mode Description Operation mode Description LCD display Standby mode Note Standby mode The inverter...

Страница 13: ...rence Code Fault Code Fault Event Icon on Fault Code Fault Event Icon on 00 Output short circuit 05 Fan locked 01 Over load time out 06 Over temperature 02 Battery weak 07 Output voltage too low 03 Ou...

Страница 14: ...ity power is normal No LED display Battery is not connected well Check the external battery cable and terminal Make sure all the battery connections to the unit are all correct Battery defect Replace...

Страница 15: ...Time 20 ms typical Waveform Simulated Sine Wave BATTERY Battery Voltage 12 VDC 24 VDC Floating Charge Voltage 13 7 VDC 0 25 VDC 27 4 VDC 0 5 VDC Maximum Charge Current 10A or 20A SOLAR CHARGER Chargi...