Installation / User Manual

Rev 3.3

(For EMEA)

ALTENERGY POWER SYSTEM Inc.

emea.APsystems.com

APsystems

Cypresbaan 7, 2908 LT,Capelle aan den Ijssel The Netherlands

Tel: +31-10-2582670

EMAIL: [email protected]

APsystems

Rue des Monts dor ZAC de Folliouses Sud-Les Echets 01700 Miribel, France

TEL: +33-481-65-60-40

EMAIL:[email protected]

© All Rights Reserved

APsystems YC600 Microinverter

Please scan the QR code to get

mobile app and more support

to help the installation.

Содержание YC600

Страница 1: ...jssel The Netherlands Tel 31 10 2582670 EMAIL info emea APsystems com APsystems Rue des Monts dor ZAC de Folliouses Sud Les Echets 01700 Miribel France TEL 33 481 65 60 40 EMAIL info emea APsystems co...

Страница 2: ...ems Microinverters to the Racking 9 4 3 4 Step 4 Ground the systems 10 4 3 5 Step 5 Connect the APsystems microinverter to AC bus cable 10 4 3 6 Step 6 Install a Bus Cable End Cap at the end of AC bus...

Страница 3: ...fied professionals should install and or replace APsystems Microinverters Perform all electrical installations in accordance with local electrical codes Before installing or using the APsystems Microi...

Страница 4: ...following the instructions when installing and using the equipment But there is no guarantee that interference will not occur in a particular installation If this equipment causes harmful interference...

Страница 5: ...ation concerning the decommissioning of equipment CE mark is attached to the solar inverter to verify that the unit follows the provisions of the European Low Voltage and EMC Directives Refer to the o...

Страница 6: ...s Microinverter System Introduction The APsystems Microinverter is used in utility interactive grid tied applications comprised of three key elements APsystems Microinverter APsystems Energy Communica...

Страница 7: ...ystem ensures that no single point of system failure exists across the PV system APsystems Microinverters are designed to operate at full power at ambient outdoor temperatures of up to 149 F 65 C The...

Страница 8: ...ultiple APsystems Microinverters in the form of single phase grid to achieve three phase grid and operates with most 60 and 72 cell PV modules Contact APsystems Customer Support for checking compatibi...

Страница 9: ...ease read all instructions and warnings in the technical documents and on the APsystems Microinverter system itself as well as on the PV array Be aware that installation of this equipment includes the...

Страница 10: ...he inverter through AC cable 4 3 3 Step 3 Attach the APsystems Microinverters to the Racking a Mark the location of the microinverter on the rack taking into acount the position of the PV module junct...

Страница 11: ...the trunk cable connector until you hear a click Try to remove it to check that it is properly locked Figure 4 Best Practice Use the Bus Cable Unlock Tool to split the connectors Figure 5 a Check the...

Страница 12: ...ules Figure 9 When connecting the 1st module the LED of the microinverter must flash three times in green This happens as soon as the cables are plugged in to show that the microinverter is working pr...

Страница 13: ...tallation map is required The layout map provided is designed to accommodate labels in vertical or horizontal orientation to meet all the field PV connections a Each APsystems Microinverter has remova...

Страница 14: ...ted to it On all switchboards in between the consumer unit and the micro generator itself On or in the micro generator itself At all points of isolation for the micro generator Figure 13 1 2 3 4 5 6 7...

Страница 15: ...hat the operation is normal 4 Connect the ECU communication gateway optional and follow the instructions in the manual Once the ECU is plugged in and set up it recognizes the microinverters then the L...

Страница 16: ...tor Interrupter GFDI error in the PV system Unless the GFDI error has been cleared the LED will remain red and the ECU will keep reporting the fault After the ground fault error is fixed follow the in...

Страница 17: ...ely a microinverter problem To troubleshoot a non operating APsystems Microinverter Follow the steps below in order to 1 Verify the utility voltage and frequency are within ranges shown in the Technic...

Страница 18: ...ct the inverter AC connector from the AC Bus 3 Disconnect the PV module DC wire connectors from the microinverter 4 Remove the Microinverter from the PV array racking B Install a replacement Microinve...

Страница 19: ...verter Please refer to the datasheet or user manual which can be download from APsystems website emea APsystems com You must match the DC operating voltage range of the PV module with the allowable in...

Страница 20: ...ncy Peak Efficiency 96 7 CEC Efficiency 96 5 Nominal MPPT Efficiency 99 5 Night Power Consumption 20mW Mechanical Data Operating Ambient Temperature Range 40 C to 65 C Storage Temperature Range 40 C t...

Страница 21: ...stems YC600 ENERGY COMMUNICATION UNIT ECU SOLAR PANEL BUS CABLE END CAP INSTALL AT THE END OF AC BUS CABLE AC JUNCTION BOX DISTRIBUTION PANEL BROWN L BLUE N YELLOW GREEN PE 9 Wiring Diagram 9 1 Sample...

Страница 22: ...ram End Cap 3 Bus Cable Unlock Tool 5 Bus Cable 8 AC Connector Male 9 C Connector Female A Y CONN Cap 4 Bus Cable Grid 1 Bus Cable 7 DC Female Connector Cap 6 DC Male Connector Cap 2 AC Branch Extensi...

Страница 23: ...60700007 3 4 wire Bus Cable End Cap 4 Bus Cable Y CONN Cap Optional 2061702007 Bus Cable Y CONN Cap 5 Bus Cable Unlock Tool Mandatory 2352000001 Y Bus Cable Unlock Tool 6 DC Male Connector Cap Optiona...

Страница 24: ...location of each microinverter in your PV installation Each APsystems microinverter has a removable serial number label located on the mounting plate Peel the label and affix it to the respective loc...

Отзывы: