APsystems YC500I-EU Скачать руководство пользователя страница 2

2017.03.20 Rev1.3

Quick Installation Guide

2

NOTE: AC connector interface as follows.

NOTE: Cover any unused connectors with

Bus Cable T-CONN Cap to protect the connectors.

Step 5.

Install a

Bus Cable End Cap

at the end

of AC bus cable

a. Strip cable jacket.

c. Insert the wires into the cable clamps.

b. Insert the cable end into the seal.

d. Rotate the nut with 3.3N·m until the

latching mechanism meets the base.

Step 6.

Place the PV modules and connect each YC500I to the PV modules

Step 7.

Complete the APsystems installation map

Each APsystems microinverter has two removable serial number labels. Peel labels off, affix one to the
respective location on the APsystems installation map, and affix another to the PV module frame such
that it is easily visible. Use the Scanning Gun to scan the serial numbers on the map into the computer or
scan by mobile phone, then complete the setting (see ECU manual).

A

B

NOTE: Sequence of steps 1~7 can change for convenience of installation.
NOTE: Using apsystems' mobile app ArrayApp can make the installation and registion much more
simple.

Step 8.

Start the operation

1. Turn on the AC circuit breaker on each Microinverter AC branch circuit.
2. Turn on the main utility-grid AC circuit breaker. Your system will start producing
power after a two-minute waiting time.

Product information is subject to change without notice.(Please download manuals at www.APsystems.com).

Nut

Seal

Body

L

PE

N