CFS SERIES OPERATION MANUAL
SECTION 4: TECHNICAL SPECIFICATIONS
Entire Contents Copyright
2016 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CFS300 Series Power Source Operation Manual
Page 28 of 156
4.3
Metering – AC Mode – Single Phase Mode
MEASUREMENT SPECIFICATIONS -SINGLE PHASE MODE
MODEL
CFS330
CFS360
Frequency
Range
0.0 - 1000.0 Hz
Resolution
0.1 Hz
Accuracy
± 0.1Hz < 500Hz, ± 0.2Hz > 500Hz
Voltage AC
Range
0 – 420 Vrms
Resolution
0.1 V
Accuracy
± (0.2% of r 0.3V)
Current RMS
Range
0.05 - 39.00 A
0.05 - 78.00 A
Accuracy
± (1% of r 0.05 A)
CF < 1.5 and Current (peak) ≤
82.8 A
± (1% of r 0.05 A)
CF < 1.5 and Current (peak) ≤
165.6 A
Current Peak
Range
0.0 - 114.0 A
0.0 - 228.0 A
Accuracy
± (1% of r 0.5A @ 40.0-70.0 Hz
± (1.5% of r 1A @ 70.1 - 500 Hz
± (1.5% of r 1A @ 501 - 1000 Hz and CF<1.5
Power
Range
0 - 3900 W
0 - 7800 W
Accuracy
±(2% of 5 W) @ 40.0-500Hz, PF>0.2
±(2% of 15 W) @ 501-1000Hz, PF>0.5
App. Power
Range
0 - 3900 VA
0 - 7800 VA
Accuracy
V x A, Calculated
React. Power
Range
0 - 3900 VAR
0 - 7800 VAR
Accuracy
Sqrt(VA
2
x W
2
), Calculated
Freq., Power & Crest Factor
See Three & Two Phase Mode