3A SERIES AC & DC LOAD OPERATION MANUAL
Page 44 of 56
7.2
Wire Size
A major consideration in making input connection is
the wire size. The minimum wire size is required to
prevent overheating and to maintain good
regulation. It is recommended that the wires are
sized large enough to limit the voltage drop at the
maximum current rating of the AC & DC load to less
than 0.5V per connection lead.
If needed, wire size can be increased by doubling
the number of wires using two space lugs per side as
shown in Figure 7-1.
Figure 7-1: Doubling wire size using spade
lugs