![Apro BON-II Series Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/apro/bon-ii-series/bon-ii-series_product-specification_2956790016.webp)
Product Specification
- 14 -
APRO Rugged Metal 2.5” SATA III MLC SSD – BON-II Series © 2015 APRO Co., Ltd.
5. Software Commands
5.1.
Write Protect
Device will become Read-Only and user will not be able to write or delete any data on the SSD.
5.1.1. Inputs for Enabling Write Protect
Table 8 – Input Write Protect Command Code (Enable)
Register
7
6
5
4
3
2
1
0
Features
17h
Sector count
41h
LBA Low
NA
LBA Mid
NA
LBA High
NA
Device
1
1
1
0
NA
Command
82h
Outputs for Enabling Write Protect
Table 9 – Output Write Protect Command Code (Enable)
Register
7
6
5
4
3
2
1
0
Error
NA
Sector count
NA
LBA Low
NA
LBA Mid
NA
LBA High
NA
Device
obs
NA
obs
DEV
NA
NA
NA
NA
Status
BSY
DRDY
DF
NA
DRQ
NA
NA
ERR
Device register
DEV
- shall specify the selected device.
Status register
BSY
- will be cleared to zero indicating command completion
DRDY
- will be set to one.
DF
(Device Fault) - will be cleared to zero.
DRQ
- will be cleared to zero.
ERR
- will be cleared to zero.