41
-
English
4.3.5 Programming the functioning
Operator functions are programmed by positioning the jumpers as described below.
Warning
!
Turn off the machine for at least 20 seconds before changing the jumper position.
•
Jp4
: Selects the type of pushbutton connected.
ON
= 2-button connection;
OFF
= 1-button connection
Selecting
JP4 OFF
(1 button) makes it possible to give the local
opening and closing commands using one button only connected
between the terminals N°1 and N° 3 (common) of the terminal
board
M2
. The control sequence is as follows:
- The fi rst press of the local button starts the
opening
cycle.
- Pressing the button during the opening cycle will
stop
the
shutter.
- Pressing the button again will start the
closing
cycle.
- Pressing the button during the closing cycle will invert the
direction of rotation of the motor (i.e. starting the
reopening
cycle).
Wing closing
last
Wing closing
first
L
N
RL2
RL1
M2
JP4 JP6
JP3
JP2
JP1
Mot2
Mot1
FE
EB
M2
Common
EB
Mot2
1 2 3 4 5 6 7 8 9
+
+
-
-
(Ø 2 x 0.5)
(Ø 2 x 1.5)
(Ø 2 x 0.75)
(Ø 2 x 0.75)
(Ø 8 x 0.25)
(Ø 3 x 0.25)
CLOSING DELAY OR SINGLE WING
Interface
module
Mot1
230 V 50 Hz AC
M1
L
N
J2
LD1
M1
J1
F1
F1
1 2
3
4 5
6 7
8 9
J2
Common
Safety
Opening
Closing
Centralised
opening
Centralised
closing
*
For lengths over 5 m
(Ø 2 x 1.5) *
(Ø 2 x 1) *
(Ø 2 x 1.5) *
(Ø 3 x 0.5) *
J2
= plug-in terminal board
NB
: If the SAFETY is not
used you must connect the
“SAFETY” terminal with the
“COMMON” terminal
•
Jp2
&
Jp3
: destined for the delayed closing of the wing
standing above.
ON
= connected;
OFF
= disconnected
•
Jp6
: Selects the functioning mode.
OFF
= man presence;
ON
= semiautomatic
Information
In the “man presence” mode, the centralised opening
and closing inputs are NOT ACTIVE.
•
Jp1
:
destined for the functioning with one or two wings.
ON
= connected= double wing;
OFF
= disconnected= single wing
Information
In the case of single-wing function, the electronic card ignores
any pre-set wing closing delay and, by pressing the CLOSE
control, the response is immediate.
Jp2
Jp3
Closing delay
ON
ON
1 second
OFF
ON
3 seconds
ON
OFF
6 seconds
OFF
OFF
12 seconds
Installation