ZONE PANEL LAYOUT
TERMINALS
1.
HVAC
– HVAC connection
2.
ZONE 1 THERMOSTAT
– Thermostat connection
3.
ZONE 2 THERMOSTAT
– Thermostat connection
4.
ZONE 3 THERMOSTAT (6203 only)
– Thermostat connection
5.
DAMPER 1
– Zone 1 damper connection
6.
DAMPER 2
– Zone 2 damper connection
7.
DAMPER 3 (6203 only)
– Zone 3 damper connection
8.
SENSOR DAT
(Discharge Air Temperature)
9.
POWER
– Zone panel, thermostat and damper power
LEDs
10.
POWER
– Green: 24VAC is present. Flashing: TDO button is pressed.
11.
HEATING
– Green: Heating is active. Flashing: DAT high temperature
limit reached.
12.
COOLING
– Green: Cooling is active. Flashing: DAT low temperature
limit reached.
13.
FAN
– Green: Fan output is active.
14.
ZONE 1
– Green: Damper is open. Red: Damper is closed.
15.
ZONE 2
– Green: Damper is open. Red: Damper is closed.
16.
ZONE 3 (6203 only)
– Green: Damper is open. Red: Damper is
closed.
17.
VACATION
– Green: Vacation mode is enabled.
BUTTONS
18.
VACATION
– Used to enable/disable Vacation mode. In Vacation
mode all zones will be controlled by the thermostat in Zone 1.
19.
TDO
(Time Delay Override) – Accelerates timing (6 seconds = 1
minute) used to speed up minimum on and off timers.
10
6
5
7
4
1
2
17
3
11
12
13
14
15
16
8
19
9
18
90-2112
FIGURE 2
– ZONE PANEL LAYOUT
4
B2206668C 61001213 AA 6202-6203 Zoned Comfort Control Install ENG-wrf.indd 4
6/14/18 3:28 PM