background image

EXTERNAL CONTROL OPTIONS

Your Aprilaire dehumidifier can be controlled with the optional Aprilaire Model 76 remote control.

Install the Model 76 in your living space and make changes to the dehumidifier setting or find out 
what the humidity level is in the crawl space from the comfort and convenience of the living space.

Refer to the Model 76 Owner’s Manual for operating instructions. Aprilaire owner’s manuals are 
available at www.aprilaire.com.

If you are interested in having a remote control installed, please consult your installing contractor.

HOW DOES THE DEHUMIDIFIER WORK?

When the dehumidifier turns on, the blower circulates the air for 3 minutes before measuring the 
humidity level of the air. The on-board control will display AIR SAMPLING, along with the measured 
humidity on the control screen. 

If the humidity of the air is higher than the setting, the compressor turns on and the control will display 
DEHUMIDIFYING, along with the measured humidity on the control screen. 

Model 76 Control

90-1854

90-1854

Once per hour the dehumidifier will measure the humidity level of the air and compare it to the humidity setting. If the humidity in your home is 
higher than the setting, the dehumidifier will dehumidify the air until the humidity level drops below the setting. 

HIGH DEW POINT / HIGH HUMIDITY ALERT

If the dehumidifier measures the dew point of the air to be 4°F or more or 6%RH or more above the setting for 72 consecutive hours, the ALERT 
LIGHT will turn on and the display will show “HI”. The dehumidifier will continue to operate as normal when the ALERT LIGHT is on. If the dew 
point falls within 4°F of the setting or relative humidity falls within 6%RH of the setting, the ALERT LIGHT will turn off.

The dehumidifier measures the conditions of the incoming air every five (5) minutes even if the dehumidifier is turned off (using the ON/OFF button) 
to determine if there is a high dew or humidity condition. Should the dehumidifier be turned off, the alert setting defaults to 57°F or 60%RH.

4

Содержание E080CS

Страница 1: ...INSTALLED BY INSTALLER PHONE DATE INSTALLED PLEASE LEAVE THIS MANUAL WITH THE HOMEOWNER TABLE OF CONTENTS PRINCIPLES OF DEHUMIDIFICATION 2 SETTING THE DESIRED HUMIDITY LEVEL 3 Dew Point Control 3 Hum...

Страница 2: ...t colder than the dew point of the incoming air The dew point is the temperature at which moisture in the air will condense much like what occurs on the outside of a cold glass on a hot summer day The...

Страница 3: ...n not running and displays the measured humidity when running The UP and DOWN arrow buttons allow the humidity level to be set from 40 to 80 relative humidity Use the ON OFF button to turn the dehumid...

Страница 4: ...will display DEHUMIDIFYING along with the measured humidity on the control screen Model 76 Control 90 1854 90 1854 Once per hour the dehumidifier will measure the humidity level of the air and compare...

Страница 5: ...er 3 Slide the filter out of the dehumidifier 4 Flush the filter with warm water and a mild detergent solution 5 Shake off the excess water from the filter 6 When inserting the filter make sure the fi...

Страница 6: ...insert can lead to condensate leaks REMOVING THE DRAIN INSERT 1 Turn the ON OFF switch OFF 2 Remove the filter access door from the drain side of the dehumidifier 3 Remove the filter from the dehumid...

Страница 7: ...OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE DEHUMIDIFIER ITSELF IM...

Страница 8: ...Aprilaire com P O Box 1467 Madison WI 53701 1467 800 334 6011 F 608 257 4357 Printed in USA 2021 Aprilaire Division of Research Products Corporation 10015562 B2209245A 1 21...

Отзывы: