Aprilaire 850 Скачать руководство пользователя страница 4

loCaTIon

InSTallaTIon InSTRUCTIonS

16" Minimum

for Steam Hose

30" Recommended

for Service Access

IMPORTANT:

Loop drain hose 

below Model 850

to provide trap.

Drain

The Model 850 must be located near the Model 800 Residential 
Steam Humidifier to minimize the length of the steam hose . If the 
Model 850 is mounted directly above the humidifier, 16” is required 
for the steam hose to make the bend . See 

Figure 2

 . 

noTe:

 The loop 

in the condensate hose is required to prevent steam from escaping 
into the drain . 
Six feet of steam hose is provided with the Model 800 Steam 
Humidifier . If the Fan Pack is mounted more than six feet from the 
Humidifier, splice in 1” copper pipe (1-1/8” O .D .) as shown in  

Figure 3

 . Due to condensation inside the hose or pipe, the output 

of the Fan Pack depends on the length of the steam hose or pipe 
connecting it to the Humidifier . When the humidifier is wired to  
120 volts, the fan pack will deliver 11 .5 gpd with up to 2 feet of hose 
or insulated pipe . Each additional 2 feet of hose or pipe will reduce 
output by approximately 1 gpd . 
Humidity behaves like a gas and under ideal conditions will expand to 
fill the space . However, air movement due to drafts or as a result of 
temperature stratification may cause uneven distribution of humidity 
within the conditioned space . To ensure even RH distribution, install 
system in a central location . If a central location is not available, it 
may be necessary to install two systems . Two systems will provide 
more even RH distribution than one .
To prevent condensation on surfaces and furnishings, install the fan 
pack so the steam being discharged has enough room to be absorbed 
into the air before encountering surfaces .

90-1551

Steam Hose

Fan

Pack

Steam Hose

1-1/2" Hose Clamp

1-1/2" Hose Clamp

1" (1-1/8" O.D.)

Insulated Copper Pipe

3/4" x 1" (7/8" x 1-1/8" O.D.)

Reducing Coupling

Humidifier

90-1565

FIGURe 3

FIGURe 2 – Side View

4

Содержание 850

Страница 1: ...ions 3 Installation Instructions Location 4 Mount Housing 6 Hose Connections 6 Electrical Wiring 7 Grille Installation 7 Start up Procedure 8 Maintenance 8 Troubleshooting Guide 9 Service Parts 10 Limited Warranty 11 READ AND SAVE THESE INSTRUCTIONS Model 850 Steam Humidifier Fan Pack Installation Maintenance Instructions ...

Страница 2: ...Disconnect electrical power before installing supply wiring or performing service or maintenance procedures on any part of the humidification system Failure to disconnect electrical power could result in fire electrical shock and other hazardous conditions These hazardous conditions could cause property damage personal injury or death Contact with energized circuits can cause property damage sever...

Страница 3: ...umidity the Model 800 Residential Steam Humidifier provides power to the Model 850 Fan Pack The Model 850 blower distributes the steam to the room When the call for humidity ends and the humidifier stops producing steam the Model 850 Fan Pack will continue to operate for 2 minutes to distribute the remaining steam before de activating Operation Figure 1 Dimensions of the Model 850 17 1 16 6 7 8 6 ...

Страница 4: ...midifier When the humidifier is wired to 120 volts the fan pack will deliver 11 5 gpd with up to 2 feet of hose or insulated pipe Each additional 2 feet of hose or pipe will reduce output by approximately 1 gpd Humidity behaves like a gas and under ideal conditions will expand to fill the space However air movement due to drafts or as a result of temperature stratification may cause uneven distrib...

Страница 5: ...5 will reduce the amount of unobstructed space required to absorb discharged steam but the distances provided are recommended minimums NOTE If operating on 240V condensation running through the steam hose back into the canister may cause a gurgling noise Install Tee Trap 4028 as shown in Figure 5 to divert condensation to drain to eliminate gurgling noise INSTALLATION INSTRUCTIONS continued 1 1 2 ...

Страница 6: ... with the Model 800 to the Model 850 and use hose clamp provided with Model 800 to secure See Figure 7 If more than 6 feet is required use insulated hard pipe as shown in Figure 3 See Model 800 manual for the affect on capacity Connect 3 8 ID condensate tubing to the Model 850 and use wire tie to secure See Figure 7 To create a trap make a 6 loop in the condensate hose See Figure 2 NOTE The 6 loop...

Страница 7: ... discharge but at least ten feet away Wire the Manual Humidistat to the Model 800 using standard 24 volt thermostat wire See Figure 8 Disconnect all power to Model 800 before wiring the Model 850 terminals to the FAN PACK terminals on the Model 800 Use standard 24 volt thermostat wire See Figure 8 Figure 8 Wiring Diagram for Manual Humidistat and Model 850 90 1816 FAN PACK HUMIDISTAT TRANSFORMER 2...

Страница 8: ...or humidification Check drain steam and condensate hoses for kinks blockages leaks or cracks Replace if necessary Ensure steam outlet of the fan pack is not blocked Maintenance Verify that there are no leaks at steam hose connections The Model 850 will operate on a call for humidity and the production of steam by the Model 800 Residential Steam Humidifier When the call for humidity is de activated...

Страница 9: ...heck location of humidistat Circuit board output Confirm 24 VAC output from Model 800 FAN PACK terminals during a call for humidity Motor failure Replace fan motor Noise Fan noise Check for obstructions or damage to fan Gurgling Add a drip tee and trap PN 4028 to the steam line as close to the Model 800 as possible to divert condensation to drain See Figure 5 If a problem arises with the Aprilaire...

Страница 10: ...SERVICE PARTS Part No Description 65 Digital Manual Humidistat 4028 Tee Trap 4851 Blower Activation Relay 4997 Condensate Tubing with Wire Ties 4998 Grille 4999 Fan 5404 Transformer 20VA 10 ...

Страница 11: ...R PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID FIVE YEAR PERIOD RESEARCH PRODUCTS CORPORATION S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OTHER THAN DAMAGES FOR PERSONAL INJURIES RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED THIS LIMITED WARRANTY IS VOID IF DEFECT S RESULT FROM FAILURE TO HAVE THIS UNIT INSTALLED ...

Страница 12: ...P O Box 1467 Madison WI 53701 1467 Phone 800 334 6011 Fax 608 257 4357 www aprilairepartners com 10010006 4 13 B2205862B Printed in U S A 2013 Aprilaire A division of Research Products Corporation ...

Страница 13: ......

Страница 14: ......

Отзывы: