COOLING OPERATION (ALL MODELS OF EQUIPMENT)

1. Set your Model 8570 programmable thermostat to the Cool mode. This is accomplished by selecting COOL from the 

Mode Menu. Consult your thermostat Owner’s Manual for details. 

2. Adjust the thermostat set point to a temperature lower than the displayed room temperature, using the Down button, so that 

a Cool call is initiated. Again, consult your thermostat Owner’s Manual for details on how to do this properly.

An LED labeled “COOL”, on the zone panel enclosure will indicate if the board is making a call for cooling. If your air conditioning
does not come on right away it may be due to the minimum-off time delay. Four minutes must elapse after the last air conditioner
cycle before it can come on again. This built-in feature ensures that the air conditioner does not cycle too frequently, which can
reduce the life of your equipment.

EMERGENCY HEAT OPERATION (Heat Pump Equipment ONLY)

Emergency Heat operation is also available if you have a heat pump and the zone panel was set up for heat pump operation
during the initial installation performed by your installer.

The Model 8570 thermostat can initiate the emergency heat mode. This is accomplished by selecting EMERGENCY HEAT from the
Mode Menu. Consult your thermostat Owner’s Manual for details.

Then, by placing the thermostat’s set point above the current temperature, Emergency Heat will energize until the thermostat is
satisfied. If any other zone should call for heat during the Emergency Heat call, it too will be satisfied by the Emergency Heat source.

NOTE: Emergency Heat is generally much more expensive to operate than the Heat Pump. Use only when necessary.
Your equipment may not include Emergency Heat.

DAMPER OPERATION

When the Aprilaire Intelligent Zoned Comfort Control Panel receives a call and turns on the appropriate equipment, it also
automatically closes the dampers that serve the non-calling zones and opens those in the calling zones. When all calls are
satisfied, the Control Panel initiates a purge cycle. During the purge cycle, the dampers maintain their last position to direct air to
the zone(s) that were calling, not affecting non-calling zones. After this purge cycle, all dampers open.

An LED on the zone panel enclosure will indicate if the damper for a zone is closed.

FAN OPERATION

The Aprilaire Intelligent Zoned Comfort Control Panel allows you to control fan operation from any zone. Dampers in zones not
calling for fan will close. If continuous fan operation is desired in all zones, the fan must be on in each zone. An LED labeled
“FAN ON”, on the zone panel enclosure will indicate if the HVAC fan is on. This can be done by selecting “ON” from the Fan
Menu on the thermostat and then selecting “YES” when prompted to “CHANGE ALL THERMOSTATS”.

Содержание 6504

Страница 1: ...Owner s Manual Model 6504 Includes Operating Instructions and Warranty Information Intelligent Zoned Comfort Control System READ AND SAVE THESE INSTRUCTIONS ...

Страница 2: ...COMFORT CONTROL SYSTEM 6 HVAC CONTROL DETAILS Heating Operation 6 Cooling Operation 7 Emergency Heat Operation 7 Damper Operation 7 Fan Operation 7 ACCESSORY CONTROL DETAILS Electronic Air Cleaner Operation 8 Ventilation Control Operation 8 Humidifier Operation 9 INTELLIGENT SHARING OF INFORMATION 10 SYSTEM PRESSURE RELIEF 10 WARRANTY INFORMATION REGISTRATION 11 ...

Страница 3: ...e controlled by the 6504 exclusively using the 8570 thermostats Aprilaire accessories such as humidifiers or air cleaners are controlled or share information through the 6504 DAMPERS Aprilaire dampers feature patented technology that eliminates the components most prone to failure with other manufacturers dampers gears These ultra reliable dampers are located in the systems supply duct work to dir...

Страница 4: ...del 8570 Premium Programmable Thermostat Model 6504 Control Panel HVAC Equipment Aprilaire Automatic Humidifier Control Aprilaire Automatic Humidifier INTELLIGENT ZONED COMFORT CONTROL MODEL 6504 SYSTEM Aprilaire Model 5000 Electronic Air Cleaner Aprilaire Model 8100 Energy Recovery Ventilator or Model 8126 Ventilation Control Damper ...

Страница 5: ...n ON Zone 4 Damper Closed FAN ON RED ON System Blower Operating OFF System Blower OFF VENT RED ON ERV or Ventilation Control Operating OFF ERV or Ventilation Control OFF EAC RED ON Electronic Air Cleaner Operating OFF Electronic Air Cleaner OFF HUM RED ON Humidifier Operating OFF Humidifier OFF HEAT RED ON Heating Equipment Operating OFF Heating Equipment OFF COOL RED ON Cooling Equipment Operatin...

Страница 6: ...erences between zones Closing interior doors is a good way to reduce the air exchange between zones and increase the temperature difference between them The following sections describe how to make Heating Cooling and Emergency Heat calls as well as how your Aprilaire Intelligent Zoned Comfort Control System can control the other pieces of your HVAC system HVAC CONTROL DETAILS HEATING OPERATION ALL...

Страница 7: ...for details Then by placing the thermostat s set point above the current temperature Emergency Heat will energize until the thermostat is satisfied If any other zone should call for heat during the Emergency Heat call it too will be satisfied by the Emergency Heat source NOTE Emergency Heat is generally much more expensive to operate than the Heat Pump Use only when necessary Your equipment may no...

Страница 8: ...he amount of time that the ERV will operate or the Ventilation Damper will be open during the Vent Cycle Period VENT CYCLE Sets the period over which the amount of ventilation run time will be summed For example if the Vent Time is set for 30 minutes and the Vent Cycle is set for 1 hour the ERV or Ventilation Damper will be operated for 30 minutes per hour An Energy Recovery Ventilator ERV like th...

Страница 9: ...on need has not been met If the AHC senses that humidification is still required when the heating system is about to turn off the Intelligent Zoned Comfort System will keep your fan operating until the need is met or for 15 minutes To prevent rapid cycling of your HVAC equipment the blower will be operated for no less than 5 minutes SECTION A SECTION B SECTION C 100 20 0 50 55 INDOOR RELATIVE HUMI...

Страница 10: ... Owners Manual for details SYSTEM PRESSURE RELIEF With a Zone Control System some form of pressure relief must be designed into the system to assure proper operation and reduce the possibility of noise due to airflow The method of pressure relief that has been designed into your system could include use of a bypass damper or the Aprilaire method of controlled pressure relief With the controlled pr...

Страница 11: ...FIVE YEAR PERIOD RESEARCH PRODUCTS CORPORATION S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OTHER THAN DAMAGES FOR PERSONAL INJURIES RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED THIS LIMITED WARRANTY IS VOID IF THIS UNIT IS NOT INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR IF THE LIMITED WARRANTY IS VOID...

Страница 12: ...prilaire products installed and serviced by qualified iHVAC contractors enhance your comfort health and energy efficiency Aprilaire Indoor Air Quality products with Engineered Simplicity Humidifiers Air Cleaners Dehumidifiers Electronic Thermostats Zoned Comfort Control Ventilation UV Germicidal Lamps P O BOX 1467 MADISON WI 53701 1467 PHONE 608 257 8801 FAX 608 257 4357 www aprilaire com 10006210...

Отзывы: