Aprilaire 10-112 Скачать руководство пользователя страница 6

- 15 -

A. TO CLEAN RESERVOIR

1. Hold bottom of reservoir (IT IS FILLED

WITH WATER) and loosen retainer knob.
Carefully lower reservoir, disengaging
from metal frame.

2. Empty water, remove partition and

reservoir liner.

3. Clean or replace reservoir liner. Reinstall

partition in liner. To replace reservoir,
hook back of reservoir over lip of dark
metal frame and tighten knob.

B. TO CLEAN HOSE

1. Disconnect hose from pump and pull

hose up through hole.

2. Flex hose to loosen scale and flush clean

with a stream of water.

3. Clean nozzle at the same time.

C. TO CLEAN PUMP

1. Remove pump impellor cap (1) by

pushing down on projecting sides (2).

2. Clean scale from inside of cover and

impellor (3) with dull blade.

3. Clean flow control (4) in pump outlet with

5/32” bit.

4. Snap pump impellor cap (1) back in

place.

5. Pull water hose down through hole,

connect to pump, and attach nozzle into
water distribution tray.

D. TO CLEAN FLOAT

1. Clean scale off float (5) and arm

mechanism (6) with dull blade.

2. Work arm mechanism (6) up and down to

dislodge any scale buildup.

E. TO OIL MOTOR

1. Disconnect water line at valve inlet and

swing line free. Disconnect the
humidistat leads.

2. Remove the three screws from the

brown motor cover and remove.

3. Use two drops SAE 20 oil in the yellow

hole on top and inside the yellow mark
on the side of the motor.

F. TO REASSEMBLE

1. Replace motor cover.
2. To reinstall reservoir, hook back of

reservoir over lip of dark brown metal
frame and tighten knob.

3. Reconnect water at valve inlet. 
4. To reinstall top cover, hook back under

lip of dark brown metal frame and tighten
two knobs.

5. Reconnect humidistat or control leads

and electrical power.

6. Turn on water supply and fill reservoir in

the fall.

7. Check unit operation.
8. Check system operation:

Manual Humidistat: Turn up humidistat to
highest setting and make sure the
furnace blower is operating. Humidifier
will operate if RH is less than 50%.
Humidifier Control: Check system
operation by setting the knob to “Test.”
With furnace blower operating and
furnace calling for heat, humidifier will
operate for one minute.

9. Set humidistat or Control to its original

position.

6

2

1

3

4

5

2

MODELS 445-448

MAINTENANCE INSTRUCTIONS for 
MODELS 445-448 RESERVOIR PUMP SECTIONS

WARNING! 120 volts may cause serious injury from electrical shock.
Disconnect power and shut off water supply before servicing.

IMPORTANT: Clean and refill reservoir, hose, pump and float every
30 days during heating season.

1. Pump Impellor Cap
2. Cap Sides
3. Impellor
4. Cap Flow Control Opening
5. Float
6. Arm Mechanism

Содержание 10-112

Страница 1: ...pressure and slip it back onto the black drain fitting Make sure the drain hose has a constant downward slope and is not flattened or blocked 10 Remove the water distribution pan cover 6 and clean V o...

Страница 2: ...Stock No 10 for Model 220 and Stock No 12 for Model 224 with colored spot up 10 Remove the drain hose from the bottom of the unit and flex it to loosen the internal calcium deposits Then flush it wit...

Страница 3: ...even water flow for maximum performance See page 3 if removed 6 Remove Water Panel evaporator 5 from the Scale Control Insert 3 Scrape the Insert with a putty knife or similar tool and flush clean wit...

Страница 4: ...mineral deposits and clean the V notches This textured surface helps ensure even water flow for maximum performance See page 3 if removed 6 Remove Water Panel evaporator from Scale Control Insert and...

Страница 5: ...fabric liner Lightly scrape out or brush off any mineral deposits being careful not to stretch or loosen the synthetic fabric liner Soaking the tray in vinegar or a lime removing agent is helpful when...

Страница 6: ...s from the brown motor cover and remove 3 Use two drops SAE 20 oil in the yellow hole on top and inside the yellow mark on the side of the motor F TO REASSEMBLE 1 Replace motor cover 2 To reinstall re...

Страница 7: ...with a new Genuine Aprilaire Water Panel Slide the pad back into the insert frame with color mark up and snap the distributon tray back into place 7 Inspect the plastic feed tube 2 by gently flexing...

Страница 8: ...lide the pad back into the insert frame with the colored spot up and snap the distributor tray back into place 7 Inspect the plastic feed tube by gently flexing it and looking for cracks or signs of w...

Страница 9: ...colored spot up and snap the distribution tray 4 back into place 7 Inspect the plastic feed tube by gently flexing it and looking for cracks or signs of wear Replace tube if it is cracked brittle or h...