Apricus AP series Скачать руководство пользователя страница 26

11. Manufacturer’s Limited Warranty

 

Apricus Solar Collector Installation and Operation Manual - International Edition

Copyright ©

 2013 – Apricus Solar Co., Ltd                                        A11-01.1.1-PB-V16                                                Page 26 of 27

AP Solar Collector

WARRANTY EXCLUSIONS

This warranty shall be void and shall have no effect if:

(a)  The  design  or  structure  of  the  Products  are  attempted  to  be 
modified  or  altered  in  any  way,  including  by  not  limited  to  attaching 

non-Apricus approved appliances or equipment;
(b)  The  Products  are  not  installed  or  repaired  in  accordance  with 

applicable local codes;
(c)  The  Products  are  not  installed  by  qualified,  suitably  licensed 

persons;
(d)  The  installer  had  not  received  Product  installation  training  by  an 

authorized Apricus distribution partner: 
(e)  The  installation  was not completed  in  line with  the  guidelines of the 

then current Apricus installation manual;
(f) System is exposed to excessive system pressure;
(g) Solar collector is exposed to flow rates in excess of 15Lpm / 4gpm;
(h) Any system component is damaged due to freezing;
(i) Any system component leaks due to corrosion;
(j)  Water  quality  is  not  within  specified  limits,  and/or  non-approved 

heat transfer liquids are used;
(k) Damage to the collector header is caused due to heat buckling;
(l) Failure is due to wind, hail, storms or other acts of God;
(m) Failure or loss of efficiency is due to lime-scale formation;
(n) Product serial tag or other identification is defaced or removed;
(o) Product is relocated from its original point of installation;
(p)  Collector  is  not  commissioned  and  is  left  to  dry  stagnate  for  a 

period exceeding 14 consecutive days; 
(q)  Any operation  exceeds the documented design limits of the system 

components or materials.

END USER OBLIGATIONS

In  order  to  obtain  performance  of  any obligation  under  this  warranty,  the 

End-User must: 

(a)  Firstly  determine  if  the  Product  is  within  the  applicable  Warranty 

Periods.  This can be  determined by referring to  the  installation record 

form,  or  alternatively  the  original  purchase  invoice.    If  neither 
documents  are  available,  the  serial  number  and  manufacturing  date 

will  need to  be  read  off the Product  serial  tag.  Some Products may be 

installed  in a location  that is not  accessible to the End-User  and so the 

information may only be obtained by a qualified service technician. 
(b)  Contact  the  company  who  installed  the  original  Product,  or,  if 

unknown or unable to be contacted, contact Apricus directly.

The following information may be required to  determine if the Product issue 

is eligible for coverage under the terms of this Limited Warranty. 

(i)  Information  related  to  the  manner  in  which  the  Product(s)  were 

installed.
(ii) The history of operation.
(iii) Any repairs that may have been made.
(iv)  Evidence that the Product(s) were  installed by a qualified, licensed 

contractor.
(v)  Evidence  that  the  Product(s)  were  installed in  accordance with  the 

applicable  Products  Installation  Manuals  and  any  special  written 

design or installation guidelines by Apricus for this project. 
(vi)  Evidence  that  the Product(s)  were  installed  in  accordance with  all 

applicable local building, plumbing and electrical codes.

CUSTOMER SATISFACTION

We  believe  you  will  be  fully  satisfied  by the  service  you  receive  from  the 
local Apricus representatives and from Apricus.  However, because our aim 
is your  complete  and  lasting  satisfaction, Apricus  adds another  feature  to 
your warranty's protection.  In the unlikely event that you feel our response 
to  a  warranty  service  request  is  not  satisfactory,  Apricus  offers  you  an 
opportunity to air your complaint in an impartial Mediation process.
The  opportunity to mediate any complaint made by an End-User  is hereby 
extended  to  all  End-Users.    If  you  are  a  Consumer  End-User,  the 
provisions  of  the  federal  Magnuson-Moss  Warranty Act  provide  that  you 
may  not  file  suit  against  Apricus  until  your  claim  has  been  submitted  to 
Mediation  for  an  informal  dispute  settlement  and  a  decision  has  been 
reached.

LIMIT OF LIABILITY

EXCEPT  FOR  THE  EXPRESS  LIMITED  WARRANTY  PROVIDED  FOR 

HEREIN  APRICUS  HEREBY  DISCLAIMS  AND  EXCLUDES  ANY  AND 
ALL  OTHER  WRITTEN  OR  ORAL  EXPRESS  WARRANTIES  OR 

R E P R E S E N T A T I O N S .  A N Y  I M P L I E D  W A R R A N T Y  O F 

MERCHANTABILITY  OR  IMPLIED  WARRANTY  OF  FITNESS  FOR  A 

PARTICULAR  PURPOSE  MUST ARISE UNDER  STATE LAW  TO APPLY, 

AND  IS  HEREBY  LIMITED  IN  DURATION  TO THE  DURATION  OF  THE 

WRITTEN  LIMITED  WARRANTIES  PROVIDED  HEREIN  UNLESS 

OTHERWISE  BARRED  BY  ANY  APPLICABLE  STATUTE  OF 

LIMITATION.  APRICUS  DISCLAIMS  ANY  RESPONSIBILITY  FOR 

S P E C I A L ,  I N D I R E C T,  S E C O N D A R Y,  I N C I D E N TA L ,  O R 

CONSEQUENTIAL  DAMAGES  ARISING  FROM  OWNERSHIP  OR  USE 
OF  THESE  PRODUCTS,  INCLUDING  PERSONAL  INJURY, 

INCONVENIENCE, LOSS OF  USE OR  LOSS  OF INCOME.   NO AGENT 

OR  REPRESENTATIVE  OF  APRICUS  HAS  ANY  AUTHORITY  TO 

EXTEND  OR  MODIFY  THIS  WARRANTY  UNLESS  SUCH  EXTENSION 

OR  MODIFICATION  IS  MADE  IN  WRITING  BY  A  CORPORATE 

OFFICER.   WHERE ANY DISCLAIMERS AND  LIMITATIONS CONFLICT 

WITH  APPLICABLE  STATE  LAW,  APPLICABLE  STATE  LAW  SHALL 

PREVAIL.
Some  states  do  not  allow  the  exclusion  or  limitation  of  incidental  or 

consequential  damages and  some  states do not allow  limitations on  how 
long implied warranties may last, so the above limitations may not apply to 

you.
WITH  RESPECT  TO  ANY  END-USER  OTHER  THAN  A  CONSUMER 

END-USER  WHICH  PURCHASES  APRICUS  PRODUCTS  FOR 

COMMERCIAL,  INSTITUTIONAL,  INDUSTRIAL  OR  OTHER  NON-

RESIDENTIAL  PURPOSES,  APRICUS  DISCLAIMS  ANY  IMPLIED 

WARRANTY  OF  MERCHANTABILITY  OR  IMPLIED  WARRANT  OF 

FITNESS  FOR  A  PARTICULAR  PURPOSE AND  FURTHER  DISCLAIMS 

ANY  LIABILITY  FOR  SPECIAL,  INDIRECT,  SECONDARY, INCIDENTAL, 

OR  CONSEQUENTIAL  DAMAGES  ARISING  FROM  OWNERSHIP  OR 
USE  OF  THESE  PRODUCTS,  INCLUDING  PERSONAL  INJURY, 

INCONVENIENCE, LOSS OF USE OR LOSS OF INCOME.
Apricus  assumes  no  responsibility  under  this  Limited  Warranty  for  any 

damage  to the Products caused  after they have  left the control  of Apricus, 

including  but  not  limited  to  damages  caused  by  any  trades  people  or 

visitors on  the  job  site,  or  damage  caused  as a  result  of  post-installation 

work.   This Limited  Warranty  shall  be  invalidated  by  any  abuse,  misuse, 

misapplication or improper installation of the Products.

GENERAL

Apricus warrants  its  Solar  Collectors and Accessories (the  “Products”)  to 

be  free  from  defects  in  workmanship  under  normal  usage  for  the 
applicable  Warranty  Period  from  the  date  of  installation.  This  Limited 

Warranty extends to the  End-User  of the product at the original  installation 

location, and is not transferable.
In  the  event  of  a  defect,  malfunction  or  other  failure  of  the  Products 

occurring  within  the  applicable  Warranty  Period  which  is  not  caused  by 

any misuse  or damage  to the  Product while  in the possession  of the End-

User, Apricus will  remedy the  failure or defect within  a  reasonable  amount 

of  time.  The remedy will  consist  of repair  or replacement of the  Products, 

or  refund  of  the  purchase  price,  in  Apricus’s  sole  discretion.  However, 

Apricus will  not  elect  to  refund  the  purchase  price  unless  it  is unable  to 
provide  a  replacement,  and  repair  is  not  commercially  practical  and 

cannot  be  made  within  a  reasonable  timeframe.    After  a  reasonable 

number  of  attempts by Apricus to  remedy any defects or malfunction, the 

End-User  will  be  entitled to  either  a  refund or replacement of  the  product 

or  its component parts.  The remedies stated herein are the  sole remedies 

for defects within the applicable warranty period.

WARRANTY PERIOD

The  “Effective  Date”  of  warranty  coverage  is  the  installation  date  as 

recorded  on  the  installation  record  form,  purchase  invoice  date,  or,  if 

neither are available, the date of manufacture plus sixty (60) days.  

Component

Coverage

Manifold Casing

Ten years parts

Copper heat transfer header

Fifteen years parts

Evacuated Tubes and Heat Pipes

Ten years parts

Mounting Frame

Fifteen years parts

Содержание AP series

Страница 1: ...AP Solar Collector Installation Operation Manual International Edition V16 May 2013 Delivering Sustainable Hot Water Solutions ...

Страница 2: ...or Mounting 9 4 1 Frame Material 9 4 2 Frame Track Leg Spacing 9 4 3 Frame Component Diagrams 9 4 3 Galvanic Reaction 15 4 4 Installation Planning 15 4 5 Frame Assembly Process 15 4 6 Manifold and Bottom Track Attachment 15 4 6 Angled Frame Kits 15 4 7 Roof Attachment Strength 16 4 8 Wall Mounting 16 5 Piping Connection 16 5 1 Collector Connection to Plumbing 16 5 2 Temperature Sensors 16 5 3 Pipe...

Страница 3: ...80 2005mm 80 2005mm 80 Overall Height 136mm 5 35 manifold only 154mm 6 06 manifold standard frame 136mm 5 35 manifold only 154mm 6 06 manifold standard frame 136mm 5 35 manifold only 154mm 6 06 manifold standard frame 136mm 5 35 manifold only 154mm 6 06 manifold standard frame 136mm 5 35 manifold only 154mm 6 06 manifold standard frame Overall Width 2 796mm 31 3 1356mm 53 4 1496mm 58 8 1636mm 64 4...

Страница 4: ...ould be handled with care when transporting to avoid breakage a If standing boxes on end adhere to the direction arrows b If lying boxes down ensure the surface is flat c Adhere to the markings on the number of boxes that may be stacked d Do not stack any heavy or sharp objects on top of the boxes e Always secure boxes in place to avoid bouncing or sliding around during transport 2 2 Component Lis...

Страница 5: ...e collector should face the equator which if in the northern hemisphere is due South and southern hemisphere is due North b The collector will still work even facing at angles East or West of the equator direction but a reduction in output will result depending on location and system configuration The diagram to the right provides a rough guide 3 3 Installation Angle a For optimal annual solar out...

Страница 6: ...sed every 3 collectors e As many as 10 x AP 30 solar collectors may be connected in series as long as flexible connectors are used and maximum flowrate limit is adhered to as outlined above g Apricus does not warrant the collector against damage resulting from poorly managed header expansion and contraction 3 9 Heat Transfer Fluids a In regions where freeze protection is not a concern water is the...

Страница 7: ... as high temperature may damage the valve and scale formation can rapidly block the vent hole The pressure and temperature relief valve on the tank may open to release pressure or heat as required Under such conditions the collector manifold will normally reach a maximum temperature of approximately 160oC 320oF Any heat returning from the collector is generally not enough to cause a continued incr...

Страница 8: ... speed corresponds to the mid range of Category 2 cyclones US Saffir Simpson Scale For higher wind speeds additional frame components lower installation angle and reinforcement of roof attachment may be required Collector mounting in high wind regions 208km h 130mph should be reviewed and where required approved in writing by a qualified engineer c Refer to section 4 for specific roof attachment d...

Страница 9: ...me materials as follows Stainless Steel Suitable for most applications Anodised Aluminium Stronger and more corrosion resistant than stainless steel these frames are suitable for high wind regions or environments that stainless steel is susceptible to tea staining discolouration surface corrosion 4 2 Frame Track Leg Spacing Collector S W 10 tubes 490mm 796mm 18 tubes 1050mm 1356mm 20 tubes 1190mm ...

Страница 10: ...f Rail FR AL RR attachment option Round Foot FR SS RF attachment option Rubber Pad FR SRPAD or FR TRPAD attachment option Horizontal Brace FR SS HB Roof Strap FR SS ST __ attachment option U Foot FR SS UF attachment option Round Foot FR SS RF attachment option Roof Rail FR AL RR attachment option Roof Track FR AL RT attachment option U Foot FR SS UF attachment option X Brace FR AL XB 30T Rear Leg ...

Страница 11: ...ail FR AL RR attachment option U Foot FR SS UF attachment option X Brace FR AL XB 30T Rear Leg FR AL RL __ 30D or 45D AL Standard Frame 30 tube Bottom Track FR AL BT 30T Front Track FR AL FT Roof Rail FR AL RR attachment option U Foot FR SS UF attachment option Tube Clips FR SS TC AL BT Rubber Pad FR SRPAD or FR TRPAD attachment option Roof Strap FR SS ST __ attachment option ...

Страница 12: ...ttachment Ideal for commercial projects where multiple collector are installed in series Name XL Roof Rail Connector Part FR SS XLRR CON Notes Connects XL Roof Rails end to end Comes with 4 x FR BOLT M8x20 SPW NL fasteners Use FR SS XLRRCON to connect rails end to end Name AL Rear Leg 30 or 45o Part FR AL RL XX XX 30D or 45D Notes Rear leg for aluminium angled frame kits supplied with attachment p...

Страница 13: ... are used All fasteners shown are included Rails and tracks are not included a b c Name Round Foot Part FR SS RF M8x50 Notes Large surface area with two holes for roof attachment Requires matching spacing of roof attachment points Comes with M8x50 Bolt for attachment to frame Tracks or Rails Name Roof Strap Part FR SS RS XX XX 60 or 100 indicating the length in cm Notes Suitable for used on flush ...

Страница 14: ...0o Angle Frame Kit APFR KIT SS __ 10D __T 10o Rear Leg FR SS RL 10D 2 2 2 3 3 SS 10o Angle Frame Kit APFR KIT SS __ 10D __T 10o X Brace FR SS XB 10D __T 1 1 1 1 1 SS 30o Angle Frame Kit APFR KIT SS __ 30D __T 30o Rear Leg FR SS RL 30D 2 2 2 3 3 SS 30o Angle Frame Kit APFR KIT SS __ 30D __T X Brace FR SS XB __T 1 1 1 1 1 SS 30 60o Adj Angle Frame Kit APFR KIT SS __ 30 60D __T 30 60o Rear Legs FR SS...

Страница 15: ...use WD 40 or similar lubricant or anti gall powder grease c Do NOT over tighten stainless steel bolts Spring washers are provided on each bolt assembly to ensure they do not loosen over time 4 6 Manifold and Bottom Track Attachment a Both the manifold and frame bottom track are secured to the frame front tracks using special attachment plates These plates are already attached to the front tracks w...

Страница 16: ... of to be installed below the collector to catch any such falling materials 5 Piping Connection 5 1 Collector Connection to Plumbing a Once the frame has been mounted and the manifold attached the manifold header may be connected to the system plumbing The plumbing connection must be completed before evacuated tubes are installed a Two header configuration are produced by Apricus but only one will...

Страница 17: ...ine after the air vent with a ball valve allowing the mains pressure water to purge the collector of air Always remove or isolate the air vent after the air purge c Low Pressure Direct Flow Open Loop Run the pump at the highest speed settings forcing air out of the manifold and back into the tank If an auto air vent is installed on the outlet of the collector air will be automatically eliminated f...

Страница 18: ...be cavitation air bubbles forming due to installation issues Pump may not have sufficient head pressure e Always use hot water rated pumps up to 110oC 232oF f Always install the pump on the flow line tank collector The pump should have an integrated non return valve or brass non return installed after the pump to prevent reverse flow of high temperature liquid which could damage the pump g Pressur...

Страница 19: ...f the heat pipes where is needs to be all boxes of tubes or individual tubes need to be turned up side down and then returned to the upright orientation In addition before installing the tube and heat pipe they should be shaken up and down a couple of times heat pipe at top to ensure the powder has all returned to the bottom 6 2 Tube Heat Pipe Insertion a The heat pipe should still be pulled out o...

Страница 20: ...tly in the bottom track g As each tube is inserted or alternatively once all tubes have been inserted secure the tubes to the bottom track using the stainless steel clips as follows STEP 1 Line up the clip with the hook on the bottom track and push down on one side until a click sound is heard STEP 2 While ensuring the clip is centered of the rubber cap push down the other side of the clip until i...

Страница 21: ... are well insulated right to the manifold casing Y N 8 Sensor cable is not in contact with any metal objects is secured in place and protected from direct sunlight Y N 9 Insulation above roof level is protected against sunlight with aluminium foil wrap or equivalent Y N 10 Controller is configured correctly with freeze setting on if required Y N 11 System is fitted with pressure relief valve on th...

Страница 22: ...components for more information The following maintenance may ONLY be completed by AUTHORISED PERSONS 8 3 Broken Tube Replacement a If a tube is broken it should be replaced as soon as possible to maintain maximum collector performance b The system will still operate normally and safely even with a tube broken c Any broken glass should be cleared away to prevent injury d To replace a tube follow t...

Страница 23: ...tion valves in the off position while the collector is full of water and exposed to sunlight as the water will heat cause a pressure increase which may rupture fittings connections In good weather the water may be hot or have built up pressure so take care when opening the drain valve STEP 3 Allow the manifold to sit in a vented state for 5 10min to allow the manifold to boil dry may need longer i...

Страница 24: ...mp running at night Bottom tank sensor not getting accurate reading Check operation of sensor Should be getting accurate reading of low tank temperature Ideal position of low tank sensor is ABOVE level of solar flow tank to solar port Fluid dumping from pressure relief valve on pump station Faulty pressure relief valve CL Replace pressure relief valve Fluid dumping from pressure relief valve on pu...

Страница 25: ...RIC Electric not heating water Check operation and power supply to element May be on timer Check if element is on off peak power supply Any changes H Replace element if faulty Check controller boost settings if controller managed H Not enough hot water IF BOILER or GAS TANKLESS Booster not heating water Check gas fuel supply H Check operation of boiler heater Check controller boost settings H Chec...

Страница 26: ...against Apricus until your claim has been submitted to Mediation for an informal dispute settlement and a decision has been reached LIMIT OF LIABILITY EXCEPT FOR THE EXPRESS LIMITED WARRANTY PROVIDED FOR HEREIN APRICUS HEREBY DISCLAIMS AND EXCLUDES ANY AND ALL OTHER WRITTEN OR ORAL EXPRESS WARRANTIES OR R E P R E S E N TAT I O N S A N Y I M P L I E D W A R R A N T Y O F MERCHANTABILITY OR IMPLIED ...

Страница 27: ...aller s Name Installation Company Name Installation Company Ph Product Serial Number s Comments Signed by Installation Officer Signed by Customer IMPORTANT NOTES 1 Please only sign if you are happy with the service provided by the Installation Officer and the system is working properly 2 Keep this document as a record of the installation as it will be required in the case of any warranty claims Apri...

Отзывы: