The Alarm Wiring Diagram 

Hardware Installation 

1.  Plug in the power connection to the IP camera. 
2.  Plug in the IP camera cable. 
3.  Confirm the correct network connection status (PC/HUB/ IP camera). 
4.  In the PC IE Browser, key in the camera’s IP online to link up to the live first 

page. 

NOTE: The user can replace the desiccant pack 

depending on how often the camera 
interior has been opened to the 
environment. Stick and fix a desiccant 
pack to the inner side of the camera with 
a two-side adhesive tape, then reattach 
the cover of the camera.

 

 

 

 

 

 

 

 

 

GND 

12V+ 

Di - 

Di +

 

Do - 

Do +

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

+12V

+12V

WARNING 

 

To prevent fire or shock hazard, avoid exposing this unit to rain or moisture.   

 

Do not block ventilation openings.   

 

Do not place anything on top of the unit that might spill or fall into it.   

 

Do not attempt to service this unit yourself, as opening or removing covers may expose you to dangerous 
voltage or other hazards. Please refer all servicing to your distributor / retailer.   

 

Do not use liquid cleaners or aerosols for cleaning.   

 

To prevent fire or electric shock, do not overload wall outlets or extension cords.   

 

PoE warning : If the PoE injector is used instead of the supplied power adaptor, all of the wiring to and from 
the injector must be routed/ installed inside a building/ plant and never routed/ installed outside of the 
building/ plant. 

 

Please only select a power adapter or power certified by UL and marked at 24Vac / 60 Hz, minimum 1A, 
class 2 or LPS. 

 

The interconnecting cables should be placed inside the UL certified Outdoor Use Conduits. 
Les câbles d’interconnexion doivent être places à l’intérieur des Conduits d’Utilisation Extérieure certifiés 
UL. 

 

If the power supply is installed outdoors, it should be a listed rainproof / watertight class 2 / LPS power 
supply or a listed power supply complying with UL60950 -1, part 1 and part 22. 
Si l’alimentation électrique est installée à l’extérieur, elle doit correspondre à une alimentation électrique de 
classe 2/LPS imperméable/étanche référencée ou une alimentation électrique référencée conforme à 
l’UL60950 -1, partie 1 et partie 22. 

 

The wiring method should comply with article 725 and article 300 in the national electrical code for the class
2 circuit and wiring in duct. 
La méthode de câblage doit être conforme aux articles 725 et 300 du code électrique national pour un 
circuit de classe 2 et le câblage dans le conduit. 

 

The entire installation should be performed by qualified personnel. 

L’installation entière doit être réalisé par du personnel qualifié. 

 

Please do not look directly at the shining, reflecting surface of the camera housing. Looking directly could 
result in eye uncomfortable. 

 

This product should not be used for the same purposes as consumer electronic devices. 

CAUTION

 

RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED 
BATTERIES ACCORDING TO THE INSTRUCTIONS. 

ATTENTION

 

RISQUE D’EXPLOSION SI LA PILE EST REMPLACEE PAR UN TYPE INCORRECT. DEBARRASSEZ-VOUS

 

DES PILES USAGEES EN SUIVANT LES INSTRUCTIONS.

3

                                                                                                                       

RMN0100560

 

Содержание LC-7553

Страница 1: ... monitor This connector adjusts and improves the images 6 AUDIO IN The connector is used to connect the audio output from other devices to the camera 7 USB port The user can use a USB device cable to connect the IP camera to the USB port on the PC 8 AUDIO OUT Provides the camera s audio signal to a speaker or stereo 9 SD SDHC CARD slot This is used for updating system software and archiving access...

Страница 2: ...IP address in the IP Camera Step 1 Plug in its power connection Step 2 Plug the USB connector in your PC and in the USB socket in the rear of the lens Step 3 A window pops up asking if you want to Run the program Open folder to view files or Take no action Choose Run the program and click OK and the USB configuration window will pop up Step 4 Set the Network setting and type in the IP address you ...

Страница 3: ...60 Hz minimum 1A class 2 or LPS The interconnecting cables should be placed inside the UL certified Outdoor Use Conduits Les câbles d interconnexion doivent être places à l intérieur des Conduits d Utilisation Extérieure certifiés UL If the power supply is installed outdoors it should be a listed rainproof watertight class 2 LPS power supply or a listed power supply complying with UL60950 1 part 1...

Страница 4: ... x input 1 x output 3 5mm earphone jack Security Multi level password protections IP address filtering HTTPS encryption User access log Protocols IPv4 HTTPS HTTP TCP UDP RTP RTCP RTSP DHCP NTP FTP SMTP UPnP ICMP ARP DDNS PPPoE SAMBA Users Access by 10 simultaneous users Network Firmware update SD card HTTP Recording SD card Pre alarm recording Yes Advanced motion 512 zones Sensitivity 0 100 Trigge...

Отзывы: