8
ALARM1 IN
ALARM4 IN
ALARM2 IN
ALARM3 IN
ALARM OUT
RECORD IN
GROUND
DISK FULL
ALARM RESET
1
2
3
4
5
6
7
8
9
5V
0V(Active)
5V
0V(Active)
1.4 ALARM In / Out
The above figure is the rear view.
1. GND:
Ground Contact.
2. ALARM
OUT
(OUTPUT):
This is an
alarm output trigger. Connect this to
external devices such as buzzers or
lights.
5V
0V(Active)
3. DISK FULL (OUTPUT):
This is a disk full
output trigger. Connect this to external
devices such as buzzers or lights.
5V
0V(Active)
4. ALARM RESET (INPUT):
This pin
connects to an alarm-clear device for
clearing an alarm.
5V
0V(Active)
5.
RECORD IN (INPUT):
This pin connects
to a record trigger device for starting a
record.
6. ALARM4 IN (INPUT):
This is an alarm
input (for CH 4), which can be
programmed in the menu system to
Normally Open or Normally Closed.
7.
ALARM3 IN (INPUT):
same as the above,
for CH 3
8.
ALARM2 IN (INPUT):
same as the above,
for CH 2
9.
ALARM1 IN (INPUT):
same as the above,
for CH 1