Overview
The IONizer is intended to be installed as part of a complete wireless design solution. IONizer’s can be
mounted just about anywhere including high posts to achieve the best results.
This chapter provides basic guidelines that pertain to each device.
Basic Guidelines
If mounted outdoors, the exposed PoE cable to the IONizer device must not exceed 140 feet (42
meters).
WARNING:
Installing the IONizer 4000 with a length of exposed PoE or secondary Ethernet cable
greater than 140 feet (42 meters) can cause severe damage to the unit or supplementary
equipment during a lightning strike.
Cable routed through conduit has a maximum length restriction of 300 feet (91 meters).
To comply with FCC RF exposure compliance requirements, the antennas used with the IONizer
must be installed with a minimum separation distance of 25.26 cm from all persons, except the
16 dBi Sector Antenna (Apprion P/N 89-1186-000) and the 19 dBi Directional Antenna (Apprion
P/N 89-1187-000) which must be installed with a minimum separation distance of 48.97 cm
from all persons.
The 16 dBi Sector Antenna (Apprion P/N 89-1186-000) and the 19 dBi Directional Antenna
(Apprion P/N 89-1187-000) are to be used for Point-to-Point operation only.
Antennas must not be co-located or operated in conjunction with any other antenna transmitter
unless separated by 20 cm or greater.
Installation must be performed using authorized cables and/or connectors provided with the
device or available from the manufacturer/distributor for use with this device.
Changes or modification no expressly approved by the manufacturer or responsible party for the
FCC compliance could void the user’s authority to operate this equipment.
Maintenance is limited to the external enclosure surface and cable connections. At no time
should the unit be opened.
IONizer’s mounted outdoors must be grounded with a connection of 1 OHM or less leading from
the external grounding stud to earth ground. When mounted indoors, the unit should be
grounded to the building’s earth ground via a connection to the external grounding stud (if
practical). Follow all national, local, and plant electrical codes.
Содержание IONizer 4000 Series
Страница 6: ......
Страница 8: ......
Страница 12: ......
Страница 29: ...Appendix A Approved Antennas Apprion Proprietary and Confidential Page 21 Vertical H Plane...
Страница 30: ...Appendix A Approved Antennas Page 22 Apprion Proprietary Confidential Horizontal E Plane...
Страница 34: ...Appendix A Approved Antennas Page 26 Apprion Proprietary Confidential E Plane...
Страница 38: ......