Connecting an Input to a Switch or Relay
STR2
switch or relay
(closed=logic low)
EN
COM+
5-24
VDC
Power
Supply
-
+
Connection Examples: EN
Connecting another drive to EN
(When output closes, input closes)
Connecting an NPN Type Proximity Sensor to an input
(When prox sensor activates, input closes)
STR
EN
COM+
-
+
Si drive
OUT+
OUT–
5-24
VDC
Power
Supply
STR2
NPN
Proximity
Sensor
EN
COM+
output
+
–
5-24
VDC
Power
Supply
-
+