Installation and Service Manual – Metered Carbon Filter
Page 14
Copyright © 2012 Applied Membranes, Inc. All Rights Reserved.
Configuring the Control Vale for Separate Source Operation
Select SEPS for control operation. For separate source operation the three wire connector
is not used.
Selection requires that a connection to a Motorized Alternator Valve (MAV) is made to the two pin connector labeled
ALTERNATOR DRIVE located on the printed circuit board. The C port of the MAV must be connected to the valve inlet
and the A port connected to the separate source used during regeneration. The B port must be connected to the feed
water supply.
When set to SEPS the MAV will be driven closed before the first regeneration cycle, and be driven open after the last
regeneration cycle.
Note: If the control valve enters into an error state during regeneration mode, the MAV will remain in its current state until the error is
corrected and reset.
Configuring the Control Valve for Use of an Outside Signal to Initiate Regeneration
Select the desired option in step 6CS.
Selection only matters if a connection is made to the two pin connector labeled DP SWITCH located on the printed circuit
board. Following is an explanation of the options:
oFF
– Feature not used.
on0
– If the dP switch is closed for an accumulative time of 2 minutes an immediate regeneration will be signaled
to the unit.
dELy
– If the dP switch is closed a regeneration will occur at the scheduled delayed regeneration time of day.
HoLd
– If the dP switch is closed a regeneration will be prevented from occurring while there is a switch closure.
Regeneration Cycle Time Settings
(Pre-Programmed to Factory Defaults)
Step 1CT
Press NEXT and
▼
simultaneously for 5 seconds and release. If screen in Step
2CT does not appear, the lock on the valve is activated. To unlock press
▼
, NEXT,
REGEN,
▲
in sequence, then press
▲
and
▼
simultaneously for 5 seconds and
release.
Step 2CT
Press
▲
or
▼
to select “FILTERING” setting.
(Note: if “SOFTENING” setting is accidentally selected, only screens additional screens will
appear – press REGEN to skip back to this screen and changing to FILTERING.)
Press NEXT to go to Step 3CT. Press REGEN to return to previous step.
Step 3CT
Adjust the length of the backwash from 1 to 95 minutes using the
▲
and
▼
buttons.
Recommended: 10
Press NEXT to go to Step 4CT. Press REGEN to return to previous step.
Step 4CT
Adjust the length of the rinse from 1 to 95 minutes using the
▲
and
▼
buttons.
Recommended: 6
Press NEXT to go to exit Regeneration Cycle Times.