4
ECHOSTAR LEGACY (DISH 500 TWIN LNB, 110°
and 119°):
Connect a cable from the LNB head and follow DISH ALIGNMENT instructions on
Page 3. The Sat Buddy 2™ does not control the switch inside the LEGACY LNB
head so the cable from the 119º side will carry the 119º signal and the cable from the
110º side will carry the 110º signal.
Connectors:
The F-81 double F female barrels should be replaced when worn. When
changing the F-81 barrels , use a 7/16” wrench. Be careful to protect and align the base
connector’s stinger when changing connectors.
Battery Charging:
While the unit is off, charge it overnight to obtain a full charge.
Do not use a wall transformer other than the one provided. Improper voltage or current
input may damage the battery charge circuit and require non-warranted service work.
Sat Buddy 2™ spare parts and associated labor:
Description
Material Labor
Battery charger wall transformer
$5.85
----
Battery charger auto cigarette charger
$8.00
----
Protective rubber boot with clip
$15.00
----
F-81 double female barrel
$2.00
----
Battery pack
$27.69
$5.00
Vinyl face adhered to metal front panel
$15.00
$5.00
Top metal end panel
$3.00
$5.00
Bottom metal end panel
$3.00
$5.00
Base connector & cable that receives F-81
$7.00
$5.00
Shipping, handling and evaluation fees are extra. Prices subject to change
without notice.
The Applied Instruments Sat Buddy 2™ has a limited warranty against defects in
materials and workmanship for a period of twelve months. Applied Instruments
agrees to repair or replace any assembly or component (except F-connectors, battery,
and neoprene carrying case) found to be defective under normal use during this
period. Applied Instruments’ obligation under this warranty is limited solely to
repairing the instrument proved to be defective within the scope of the warranty
when returned to the factory. Transportation to the factory is to be arranged and
prepaid by the customer. Authorization by Applied Instruments is required prior to
shipment.
Applied Instruments assumes no liability for secondary charges or consequential
damages and, in any event, Applied Instruments’ liability for breach of warranty
under any contract shall not exceed the purchase price of the instrument shipped, and
against which a claim is made.
Any application recommendations made by Applied Instruments for the use of its
products are based upon tests believed to be reliable, but Applied Instruments makes
no warranty of the results to be obtained. This warranty is in lieu of all other
warranties, expressed or implied, and no representative or person is authorized to
represent or assume for Applied Instruments, any liability in connection with the
sale of Applied Instruments products other than that set forth herein.
Please keep your receipt of purchase to verify purchase date.
If it becomes necessary to have your Sat Buddy2 ™ serviced, contact:
Applied Instruments, Inc.
5230 Elmwood Avenue
Indianapolis, IN 46203 USA
Tel. (317) 782-4331
Fax (317) 786-9665
www.appliedin.com
Revised 10/2006
MAINTENANCE
WARRANTY
APPLICATION NOTES
Con’t