Activating the “SYSTEM OFF” switch should be done 
with care because there will be no heating or cooling 
operation even though there may be a demand - a 
room could potentially go into a freezing condition. 
Once a comfortable temperature setting is 
established, no other adjustments are necessary, 
except for fan speed, which is adjusted using the fan 
speed control knob at the unit.  

WALL THERMOSTAT OPERATION 

Heat 

Sets the unit into heating mode. 
Initiates heating when room 
temperature falls below set point.  

Off 

Disables heating and cooling 
modes, but allows control of fan. 

Cool 

Sets the unit into cooling mode. 
Initiates cooling when room 
temperature rises above set point. 

Auto 

(not shown) 

Found on automatic changeover 
thermostats only. Allows the 
thermostat to decide whether it 
should be in the heating or cooling 
mode. Usually a 4 F

°

 differential or 

“deadband” will exist between 
heating and cooling set points to 
prevent rapid switching between 
modes. 

Adjustable 
Temperature 
Setting

 

Establishes the “set point”, or 
desired room temperature. 

Fan On 

Synonymous with “Fan 
Continuous”. Fan will continue to 
run after the heating and cooling 
function has cycled off. Fan will 
continue to run even when mode 
switch is in Off position. 

Fan Auto 

Synonymous with “Fan 
Intermittent”. Fan will cycle on and 
off with the heating cycle or 
cooling cycle, and will not operate 
between cycles. 

UNIT MOUNTED CONTROLS 

   Dial Plate and Rotary Switch 

ROTARY SWITCH 

The rotary switch and dial plate are found under the 
control door, which is located at the top right corner 
of the unit. The knob can be rotated to the left or to 
the right of the “Off” position. Heating output is not 
affected by fan speed. The settings are addressed in 
the following table: 

ROTARY SWITCH OPERATION 

Fan ‘3’  

High Speed. Selects highest fan 
speed for maximum cooling capacity, 
maximum airflow, maximum air throw, 
hence maximum air circulation. 

Fan ‘2’  

Medium Speed. Selects medium fan 
speed for a slightly reduced cooling 
capacity, at midrange airflow, and 
operation at a reduced sound level. 

Fan ‘1’  

Low Speed. Selects lowest fan speed 
for maximum air dehumidification and 
operation at the lowest sound level. 

IMPORTANT:

 If the compressor is running in cooling 

mode, and then the unit is switched off, wait at least 
three minutes before switching the unit back on. This 
prevents cycling the compressor overload switch 
unnecessarily.  Similarly, if the power has been 
interrupted, it is recommended that the unit be 
switched off and not switched on again until power 
has been restored for at least 3 minutes.  

NOTE: 

The unit uses time delay relays to respond to 

commands from the wall thermostat. Therefore, there 
will be delayed responses when switching from one 
function to another – please be patient. 

FRESH AIR CONTROL 

Refer to the standard unit Installation Instructions for 
operation and location of fresh air door control lever.  

Содержание DMQC Series

Страница 1: ...rmostat depends on accurate room temperature sensing Be conscious of locating the thermostat where temperatures near the thermostat are not representative of room temperature For example do not install the thermostat where it is subjected to direct sunlight other sources of heat or cold drafts including air discharged from a supply air register A common error is not sealing the hole in the wall wh...

Страница 2: ...cle and will not operate between cycles UNIT MOUNTED CONTROLS Dial Plate and Rotary Switch ROTARY SWITCH The rotary switch and dial plate are found under the control door which is located at the top right corner of the unit The knob can be rotated to the left or to the right of the Off position Heating output is not affected by fan speed The settings are addressed in the following table ROTARY SWI...

Страница 3: ...nning too slow and drawing high amps Compressor may be miswired Check capacitor Compressor may be seizing if so replace compressor Indoor room temperature too cold Compressor will cycle on and off by command of the indoor coil freeze protection device Compressor Short Cycles Outdoor temperature too cold Compressor is not intended to operate at cold outdoor temperatures Compressor will cycle on and...

Страница 4: ... Unit Rattles or is Noisy Rubbing of fan or blower on housing Ascertain cause and correct Check during operation System switch set OFF on wall thermostat Switch to HEATING Faulty thermostat Test and replace if necessary Fuse or circuit breaker tripped Replace or reset as necessary Cord not plugged in Plug in Defective switch Test and replace if necessary Defective heater Inspect and replace if nec...

Отзывы: