6.2.2.
Binary Output ICD
Binary output is provided using Trimble GSOF message format. The Figure 31 represents
binary message selection selectable through web user interface.
Figure 45: Binary Message Selection
GSOF messages are outputted as a part of Report Package 40H represented in Table 5:
General Output Record Report 40H.
Table 5: General Output Record Report 40H
Byte # Item
Type
Value
Description
0
STX
CHAR
02h
Start transmission
1
Status
CHAR
Bit 1 -> Low
battery
Bits0,2-7->
Reserved
2
Packet Type
CHAR
40h
Report package 40H