9
(4) Resistance :
Ω
Range
Resolution
Accuracy
Max. Open
Circuit Voltage
Overload
Protection
4K
Ω
1
Ω
3.3V
600V r.m.s.
40K
Ω
10
Ω
±
(1.0% rdg + 2 dgt)
Instant Continuity Description :
Built - in buzzer sound when resistance is less than 100
Ω
.
(5) DCA : A
Range
Resolution
Accuracy
Overload Protection
0 ~ 400A
0.1A
AC 2000A
for 1 min.
400 ~ 600A
1A
600 ~ 1000A
1A
±
(1.9% rdg + 5 dgt)
±
(1.0% rdg + 3 dgt)