Aponorm BASIS PLUS BLUETOOTH Скачать руководство пользователя страница 1

Upper arm

BASIS CONTROL

PLUS

Automatic multiple measurement

for increased measuring reliability

* Functional warranty of 2 years on the cuff as a wear part

Traffi c light 

display

2

users

Arrhythmia  

detection

storage slots

Instructions for use

Also suitable for:

YEARS

WARRANTY

 *

Multiple 

measurement

Diabetics

Содержание BASIS PLUS BLUETOOTH

Страница 1: ...for increased measuring reliability Functional warranty of 2 years on the cuff as a wear part Traffic light display Traffic light 2 users Arrhythmia detection storage slots Instructions for use Also...

Страница 2: ...aponorm Basis Control PLUS 2 10 11...

Страница 3: ...otect from moisture Before use carefully read the operating instructions Display indication 12 Systolic value 13 Diastolic value 14 Pulse indicator 15 MAM mode multiple measurement mode active 16 Batt...

Страница 4: ...instrument was developed in collaboration with physicians and clinical tests prove its mea surement accuracy to be of a very high standard If you have any questions or problems or want to order spare...

Страница 5: ...hythmia detector PAD 10 4 Data memory 11 Viewing the stored values 11 Clearing all values 11 5 Battery indicator and battery change 11 Batteries almost flat 11 Batteries flat battery replacement 11 Wh...

Страница 6: ...plays the time 24 The date however is only required for the memory display If you want to change the date and time again press and hold the MAM time button 4 down for approx three seconds until the ye...

Страница 7: ...order to return to the normal mode indi vidual measurement press the MAM button again until the MAM symbol is no longer displayed During the measurement in the MAM mode the number 1 2 or 3 at the bott...

Страница 8: ...pressure 1 Press the On off button to start the measure ment 1 2 The cuff will now inflate automatically Relax do not move and do not tense your arm musc les until the measurement result is displayed...

Страница 9: ...logist Manual inflation In case of very high systolic blood pressure e g exceeding 135 mmHg it can be of use that you determine the pressure yourself Press the On off button after the monitor started...

Страница 10: ...tores the last 99 readings for each user Viewing the stored values Press the M button 3 briefly while the monitor is switched off Now the display changes over to the data memory display indicated by M...

Страница 11: ...tery sym bol 16 will flash as soon as the device is switched on You cannot take any further measurements and must replace the batteries In the event of a battery change or power failure the memory ret...

Страница 12: ...nto the wall socket When the mains adapter is connected no battery current is consumed We recommend to have batteries in the monitor even with mains operation just as a back up They ensure that in the...

Страница 13: ...naccurate and no result can therefore be displayed Read through the check list for perfor ming reliable measure ments and repeat the measurement Error Designa tion Potential cause and remedy ERR 6 MAM...

Страница 14: ...itted to your arm Do not use this monitor close to strong elec tromagnetic fields such as mobile telephones or radio installations We recommend obser ving a minimum distance of 3 3 m from such devices...

Страница 15: ...s Monitor care Clean the monitor with a soft dry cloth only Cleaning the cuff Remove stains on the cuff carefully with a damp cloth and soapsuds or a commercial disinfectant WARNING Do not wash the cu...

Страница 16: ...rming part of the product We grant a functional guarantee of 2 years on the cuff tightness of the inner chamber Warranty term The warranty covers a period of 5 years from the date of purchase warranty...

Страница 17: ...the Federal Republic of Germany Date 02 2019 10 Technical data Operating 10 40 C 50 104 F conditions 15 95 relative maximal humidity of air Storage 20 55 C 4 131 F conditions 15 95 relative maximum hu...

Страница 18: ...18 Average monitor 5 years or life 10 000 measurements accessories 2 years This monitor complies with the requirements of the Medical Device Directive 93 42 EEC Technical alterations reserved...

Страница 19: ...ife ch Functional overview Important advice Inthedownloadareaofwww aponorm deyoufindtheseinstructionswithupdates alsoindigitalformfordownload alsoinGerman Turkish FrenchandRussian Homepage Cuff check...

Отзывы: