How SmartStart works 

When power is applied to the DVR it will fully power up. The SmartStart code then maintains a running 
average of the input voltage as a Baseline Voltage. If the voltage goes up, a new Baseline Voltage is 
recorded. If at any point the voltage drops by 0.5v, the SmartStart code signals a shutdown. The timers 
of the DVR will then allow the system to shut down. When the system is off and then a voltage jump up to 
the Baseline Voltage is detected, the system will restart. 
 
The SmartStart code will remember the Baseline Voltage until the system is fully powered down, and 
power is removed from the DVR system.  

SmartStart Usage Scenarios 

 

If the user has a vehicle that is routinely left with the ignition in the ACC on, and the engine off, 
and wants the system to power 

down so the batteries don’t run down, select SmartStart ON. 

This applies to both vehicles that maintain power to the CLA when ignition is off, and those that 
power down the CLA when ignition is off. 

 

If the user would like to use a vehicle and get the maximum recording time, without protecting 
the battery, select SmartStart OFF. 

 

If the Rapid Deployment Kit is used with an alternative power source, like a wall adapter, or 
battery bank, select SmartStart OFF. 

 

If a system is Operating with SmartStart ON, and the user would like to record after the engine 
is turned off: turn off the engine, remove the power cable from the CLA, allow the system to 
completely power down with no panel LED activity for 15 seconds, then plug in the CLA. The 
system will power on and resume recording, then it will shut off after the battery voltage drops 
0.5v. This will protect the battery and allow recording to happen without the engine running. 

 

When SmartStart is on, and the system recognizes the engine is off, internal timers that cause a 
long shutdown delay may cause the battery voltage to drop more than 0.5v, and could cause 
the vehicle to not be able to start. Internal Power-Down timers should only be used when 
considering the specific vehicle capabilities. 

 

If the User would like to switch SmartStart modes, remove power from the CLA, toggle the 
SmartStart switch, allow the system to completely power down with no panel LED activity for 15 
seconds, then restore power to the unit. It will operate in the new power mode. 

 

 

Содержание RoadRunner HDX

Страница 1: ...HDX Rapid Deployment Kit High Definition Portable Mobile Recording System User Guide and Instruction Manual Version A Rev 1 0 ...

Страница 2: ... ENVIRONMENT THIS EQUIPMENT GENERATES USES AND CAN RADIATE RADIO FREQUENCY ENERGY AND IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTION MANUAL MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE USERS WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT THEIR OWN EXPENSE WARNING CHANGES...

Страница 3: ...acement Parts When replacement parts are required be sure the service technician has used replacement parts specified by the manufacturer Unauthorized substitutions may result in fire electric shock or other hazards 12 Safety Check Upon completion ofany service or repairs to this equipment ask the service technician to perform safety checks to determine that the equipment is in proper operating co...

Страница 4: ...RoadRunner HDX Rapid Deployment Kit High Definition Portable Mobile Recording System This page left intentionally blank ...

Страница 5: ...Contents and Configuration 2 Chapter 3 Installation 4 Rear Panel Connectors 4 Front Panel Control 6 Mounting the Cameras 6 Mounting the Rapid Deployment Kit 7 Chapter 3 Operation and Configuration 8 Turning on the Power 8 Initial Unit Setup 8 Appendix 9 Map of Setup Screens 9 Troubleshooting 10 System Log Notices 10 Error Code Notices 11 ...

Страница 6: ...RoadRunner HDX Rapid Deployment Kit High Definition Portable Mobile Recording System This page left intentionally blank ...

Страница 7: ...g equipment and for rental vehicles The Rapid Deployment Kit is designed for mobile applications and operates using 9 to 36 volts DC which makes it compatible with the typical 12 VDC and 24 VDC power systems found on vehicles As the Rapid Deployment Kit is designed for temporary installation in vehicles it includes a Cigarette Lighter Adapter CLA power cord within the case along with Cameras and o...

Страница 8: ...rd to the ignition key position other vehicles power the CLA only when the ignition key is in the ACC or ON position To turn on the DVR only when the vehicle engine is running the DVR monitors the input voltage to the DVR this is the SmartStart ON mode of operating If the vehicle automatically disconnects power to the CLA when the ignition key is turned off the DVR will power down this is the Smar...

Страница 9: ...d like to use a vehicle and get the maximum recording time without protecting the battery select SmartStart OFF If the Rapid Deployment Kit is used with an alternative power source like a wall adapter or battery bank select SmartStart OFF If a system is Operating with SmartStart ON and the user would like to record after the engine is turned off turn off the engine remove the power cable from the ...

Страница 10: ...requirement 9 36VDC 30A during operation The Rapid Deployment Kit operates on a wide range of vehicles It accepts power inputs ranging from 9 to 36 VDC This allows it to operate on both 12 and 24 volt systems The Cigarette Lighter Adapter of the provided power cable includes a 15 AMP fuse to protect the vehicle and Rapid Deployment Kit from hardware failures Network Port The Recorder can be connec...

Страница 11: ...the lights are active The red light will also indicate a recorder fault The Event button includes with a magnetic mount and is included within one of the Antenna heavy duty zippered pouches WiFi Cell Connectors The Rapid Deployment Kit includes two antenna modules in separate heavy duty zippered pouches Ports are provided for two antennas for two separate Cradlepoint wireless routers Two WiFi wire...

Страница 12: ...E HEATER HAS BEEN OPERATING IN LOW TEMPERATURES DURING OPERATION OF THE HEATER THE TEMPERATURE OF THE DRIVE MAY INCREASE CAUSING INJURY Drive Assembly Two removable Smart Storage Modules can be inserted into the Drive Assembly The Storage Module can be removed to view the video on the personal computer or utilized in another Recorder The door must be open and the power LED must be off with the pow...

Страница 13: ...f the box shifting in the event of an accident the box should be strapped in place Mounting straps are not included within the Rapid Deployment Kit WARNING IT IS IMPORTANT THAT THE RAPID DEPLOYMENT KIT CASE HARDWARE AND CABLES DO NOT INTERFERE WITH ANY OF THE VEHICLE S CONTROLS ARE NOT POSITIONED TO PLACE PASSENGERS AT RISK IN THE EVENT OF AN ACCIDENT AND ALSO DO NOT BLOCK THE DRIVER S VIEW OR REA...

Страница 14: ...C WARNING DO NOT TOUCH THE BOTTOM OR TOP OF THE REMOVABLE DRIVE WHEN REMOVING IT AFTER THE HEATER HAS BEEN OPERATING IN LOW TEMPERATURES DURING OPERATION OF THE HEATER THE TEMPERATURE OF THE DRIVE MAY INCREASE CAUSING INJURY Initial Unit Setup Before using the Recorder for the first time establish the initial settings Install the RsM Software Program RoadRunner Secure Management SoftwareTM on a PC...

Страница 15: ... Screens MENU SYSTEM CAMERA RECORD General Date Time User Storage Power Management Monitoring General Stream Audio Advanced Setup Upgrade General Schedule EVENT DEVICES NETWORK NOTIFICATION Alarm In Video Loss Text In Video Analytics Audio Detection Alarm out GPS General IP Address FEN Schedule Callback Mail ...

Страница 16: ...nformation and troubleshooting assistance System Log Notices Boot Up Schedule On Clip Copy Duration of Video Shutdown Schedule Off Clip Copy Camera Restart No Storage Found Callback Fail Upgrade Storage Wrong Format Factory Reset Upgrade Fail Storage Formatted ACC On Power Failure Clear All Data ACC Off Time Change Clear Disk Key On Time Zone Change Format Disk Key Off Time Sync Disk Full Heater O...

Страница 17: ...anged 300 Remote connection failed 11 Appending failed 301 Remote network error 12 Bad sector 302 Remote upgrade is not authorized 13 No executable file 303 Saving remote package failed 14 Opening executable file failed 304 Remote upgrade is cancelled by the user 15 Writing executable file failed 400 USB device mounting failed 16 Creating image failed 401 Reading upgrade package on the USB device ...

Отзывы: