10
10
Metro
etl
Operator Wiring
Green/yellow wire (case ground)
attach to foundation box.
White to blue from closed
limit switch
Orange to blue from open
limit switch
Green to both black wires
from limit switches
From motor
- Cable / Harness
Motor wire
Cable
Diagram for left mounted operator
NOTE: For right mounted operators, blue motor wire goes to red cable wire, brown motor wire to black cable wire.
To verify motor wiring
–
place gate half way open, plug main harness into emergency bypass for 2 seconds. Gate
should open if it closes, reverse red and black wires.
To verify limits, enable LEDs on board
–
verify open limit when gate opens and closed limit when closed - If
reversed
–
swap limit switch positions.
Brown - Red
Blue
- Black
Black
- Yellow
Grey
- Blue
Open limit switch
Close limit switch
Содержание METRODUALetl
Страница 7: ...7 METROETL...
Страница 12: ...12 SIREN GND OPERATOR CABLE BLUE METRO Wiring Diagram YELLOW YELLOW RED BLACK...