19
AIM-4SL Hardware Manual
© 2011 Apollo Security Inc.
Figure 3.4.1.2 RS-485 Device Connections.
The AAN-100 serves as the master on the line and the
field devices are slaves. The receive lines of the master are wired to the transmit lines of the slaves, and the
receive lines of the slaves are wired to the transmit of the master.
3.5
Card Reader Wiring
Up to four card readers can be connected to the AIM-4SL. Card readers with standard Wiegand output are
supported, including magnetic stripe, proximity, bar code, smart card, biometric, keypad, etc. It is not
necessary for the readers to be identical on each connection port, i.e. up to four different reader types can be
used simultaneously.
Each reader connection consists of connection terminals for VDC Output and Ground, Data 1 Signal, Data 0
Signal, Beeper control, and multiple LED control (red, green, and yellow). The wiring to the reader should be
made using 24 AWG shielded cable with 4 twisted pairs (Belden 9504 or equivalent). Do not exceed
500 feet (152 m) between the AIM-4SL and reader. Connect the shield drain wire of the cable at the GND
terminal of the appropriate reader connector on the AIM-4SL. Carefully insulate the drain wire with sleeving
for a reliable installation.
Power for the reader connection (VDC) is derived from the power input (VIN) for the AIM-4SL and is
distributed between the four reader connections. Thus, voltage to the reader power connection will roughly
equal the voltage supplied to the AIM-4SL power input. There must be sufficient power to supply the load of
all readers as well as for the AIM-4SL itself (+12 to +24VDC @ 250 mA). If the readers have a greater total
power requirement, or if there are other wiring concerns, external power supplies should be used to power
the readers. In this case, only connect the reader power lines to the external power supply; do not connect
the reader to two power supplies.
For basic operation of the reader, at a minimum the Data 0 and Data 1 wires must be connected from the
reader to the AIM-4SL and power supplied to the reader. LED and beeper control lines do not have to be
connected, but in this case, the LEDs and beeper may not function on the reader.
Содержание AIM-4SL
Страница 6: ...Part Introduction I ...
Страница 9: ...Part Hardware Layout II ...
Страница 19: ...Part System Wiring III ...
Страница 36: ...Part Troubleshooting IV ...
Страница 38: ...Part Specifications V ...
Страница 40: ...Part Supplemental Figures VI ...
Страница 41: ...36 Supplemental Figures 2011 Apollo Security Inc 6 Supplemental Figures ...
Страница 42: ...37 AIM 4SL Hardware Manual 2011 Apollo Security Inc ...
Страница 43: ...38 Supplemental Figures 2011 Apollo Security Inc ...
Страница 44: ...39 AIM 4SL Hardware Manual 2011 Apollo Security Inc ...
Страница 45: ...40 Supplemental Figures 2011 Apollo Security Inc ...
Страница 46: ...41 AIM 4SL Hardware Manual 2011 Apollo Security Inc ...
Страница 47: ...42 Supplemental Figures 2011 Apollo Security Inc ...
Страница 48: ...Part Table of Figures VII ...
Страница 50: ...Part Revision History VIII ...