Installer Menu 2 & 3 (Output Configuration)
OP1 Threshold 00500W
Temp Control T/Stat
ON Del 10 OFF Del 10
Min ON Time 000 Mins
Apollo GEM
Installation Manual
OP1 Variable 03000W
Temp Control T/Stat
Mode:
Variable
Threshold
Tmr Only
Output
Number
Load Power
100W - 12000W
Temperature Control:
T/Stat
Sensor
None
Output Options when output mode is Variable
Load Power
(Threshold Setting)
100W - 16000W
Temperature Control:
T/Stat
Sensor
None
Mode:
Variable
Threshold
Tmr Only
Output Options when output mode is Threshold
ON Delay:
Delay in seconds for
export power to be
above threshold
before
output is
turned
on. (00-99)
OFF Delay:
Delay in seconds for
export power to be
below threshold
before
output is
turned off. (00-99)
Min ON Time:
Time in minutes the
output must remain
on once turned on.
(000-240)