D
o
cu
m
e
n
ta
ti
Revision 3, August 2015
Apollo Solar Electric Ltd
Generated Energy
Management
System
User Manual
and
Installation Manual
Страница 1: ...Documentation Revision 3 August 2015 Apollo Solar Electric Ltd Generated Energy Management System User Manual and Installation Manual...
Страница 2: ...0 Error Message Display 12 Boost Mode 13 Setting the Timer 14 Legionella Control Function 15 Setting Water Temperatures 17 Apollo GEM Set up Mode 19 User Set up Screens 20 Installer Set up Screens 21...
Страница 3: ...lo GEM Current Sensor 35 Sensor Transmitter Installation Wireless Systems 37 Sensor Transmitter Initial Checks 37 Setting up the System 38 Factory Configuration 38 Setting wireless mode operation 38 I...
Страница 4: ...e Carefully observe the following instructions Installation and maintenance must be carried out by a competent person in compliance with the manufacturer s instructions the relevant wiring regulations...
Страница 5: ...water system In threshold power mode Apollo GEM uses a programmable threshold to determine when enough surplus power is available from the micro generation system to power a connected appliance This...
Страница 6: ...ion may also be required if the water heater or other appliance connected to the controller does not have a dedicated circuit wired back to the consumer unit The picture below shows the Apollo GEM con...
Страница 7: ...e optional wireless sensor transmitter kit the current sensor is connected to the sensor transmitter unit instead of the Apollo GEM controller unit Apollo GEM User Manual Apollo GEM Current Sensor Opt...
Страница 8: ...would not be suitable for connection to the Apollo GEM variable power output because such devices always expect to be powered by the full mains voltage Connection of most appliances to the variable po...
Страница 9: ...l be heated at full power regardless of whether any surplus PV power is available This allows water to be heated during off peak electricity times or in the early morning before any PV power is genera...
Страница 10: ...e display to show the total export units saved and export units saved during the last 30 days Apollo GEM User Manual Mon 13 25 Temp 51 C Optimising 1 ON Heater1 ON 1920W Exporting 0 3KW Current Hot Wa...
Страница 11: ...ected to output 1 will be turned on when the threshold is reached This indicates that the optimising has been turned off by the user in the set up menu All surplus generated energy will be exported Op...
Страница 12: ...ess systems only Check the power sensor is on and is showing a green or orange light Optimising will be disabled Pairing with a new sensor has been requested from the set up menu or at new installatio...
Страница 13: ...output 1 A second press of the boost button within 2 seconds will turn on the boost for output 2 The system function display will then change to show Boost 1 ON or Boost 2 ON and the remaining time bo...
Страница 14: ...reen 2 for Monday to Friday times and screen 3 for Saturday and Sunday times The timer programming screen is shown below To make a pair unused program the start time to 00 00 NOTE It is not possible f...
Страница 15: ...ems where the temperature remains between 20 and 45o C How do people get it People can catch legionnaires disease by inhaling small droplets of water suspended in the air containing the bacteria such...
Страница 16: ...en the programmed temperature is reached the cycle will terminate and normal PV optimising will resume If the Apollo GEM tank temperature sensor is not used the temperature set by the electric hot wat...
Страница 17: ...t hot water temperature Better temperature control Water temperature is more accurately controlled than with the electric water thermostat Programmable temperature The hot water temperature can be pro...
Страница 18: ...tric hot water thermostat interfering with the Apollo GEM sensor temperature control Some standard electric water thermostats can only be adjusted up to a maximum of 60 or 65 o C and therefore a highe...
Страница 19: ...ow keys To move to then next setting briefly press the SET key When the last setting on the screen has been reached pressing the SET key will advance to the next set up screen When the last item on th...
Страница 20: ...perature Settings Tmr Boost Temp sets the temperature when in timer or boost mode Optimiser Temp sets the temperature when using excess generated energy in optimiser mode Screen 5 Legionella Control P...
Страница 21: ...up Functions Set up for unit mode and output priority and radio link sensor pairing if in wireless mode Screen 7 Output 1 Set up Functions Set up for output 1 variable mode shown Screen 8 Output 2 Se...
Страница 22: ...2 Output Power Share Mode Only output 1 or output 2 used Power is diverted to second output when first output set temperature is reached Available power is shared equally between the two outputs Sing...
Страница 23: ...outputs must not be greater than 3KW Load can be up to 16KW per load if used with external contactors Single Output Mode 2 Output Priority Modes 2 Output Threshold Mode Power is diverted to second ou...
Страница 24: ...nce power is then diverted to output 2 in variable mode when the set temperature is reached on output 1 Apollo GEM User Manual Mixed 2 Output Priority Mode Initially power is diverted to output 1 in v...
Страница 25: ...nly output 1 will be available Output 2 is used to control the external contactors Apollo GEM User Manual Total Load 12KW Output L1 3KW Load Output L2 3KW Load Supply 2 3KW Load Supply 3 Output L3 Out...
Страница 26: ...eshold mode operation can support loads of up to 16KW per output if the load is connected to the output via a suitably rated contactor Apollo GEM Installation User Manual Apollo GEM User Manual Output...
Страница 27: ...ULATIONS A means of disconnection from the supply having at least 3mm contact separation in both poles must be incorporated in the fixed wiring If in doubt consult a qualified electrician Electric Wat...
Страница 28: ...such that a minimum of 50mm clearance is provided on both sides of the unit Cover removal Remove the four screws on the front of the unit and the front cover will then slide off Cable entry Knockouts...
Страница 29: ...ricity company supply connection is remote from the consumer unit Important 1 If the Apollo GEM controller is located remotely from the water heater e g next to the consumer unit a double pole isolato...
Страница 30: ...ly wired earth connections not shown for clarity GEM Controller Apollo GEM Current Sensor Clamp Electric Hot Water Heater Element Double Pole Electric Hot Water Isolator with 13A fuse adjacent to wate...
Страница 31: ...c water MCB or Fuse Direct wired electric hot water circuit before Apollo GEM installation Neutral and earth connections not shown for clarity Live to Electric hot water element Direct wired electric...
Страница 32: ...itter Water Heater Element Immersion Double Pole Isolator 16A Immersion Circuit PV System Isolator 6A Transmitter Supply Circuit Transmitter can also be plugged into standard 13A socket A double pole...
Страница 33: ...ed Temperature Sensor Connection If used the temperature sensor is plugged into a 4 pin RJ11 connector situated at the front of the main Apollo GEM circuit board marked TEMP SENS TERMINAL CONNECTION L...
Страница 34: ...ly made to the Apollo GEM controller Prepare the cable end as shown Insert the wire fully into the terminal Use the correct size screwdriver and ensure terminal screws are tight but not over tight Che...
Страница 35: ...of the PV system connection If the PV system is connected to the main consumer unit then the current sensor may be clamped round the incoming supply to the consumer unit If the PV system is connected...
Страница 36: ...e sensor can be installed on the neutral supply cable instead of the live In this case the label This side facing main meter should face away from the utility meter Henley Block PV System Isolator Cur...
Страница 37: ...light followed by the Green LED and then both LEDS should go out After start up either the green or orange LED should flash If power is currently being imported the green LED will flash If power is cu...
Страница 38: ...mode for standard 3KW heater Temperature control by heater thermostat Timer disabled Setting wireless mode operation The factory setting is for non wireless operation If wireless operation is required...
Страница 39: ...eater is working and b The power measuring system is working correctly Check That the display shows Boost 1 ON 60 mins and that the measured import power has increased by approximately the heater powe...
Страница 40: ...Apollo GEM systems are installed in overlapping coverage e g next door properties When displaying the Pairing New Sensor message Apollo GEM will search for a sensor signal which is transmitting the fi...
Страница 41: ...al Set up Screen 6 Installer Menu Page 1 change wireless parameter to START PAIR to pair new controller transmitter When the system is paired continue 6 Briefly press the Boost button to start boost m...
Страница 42: ...figuration options for output 1 and output 2 respectively e g load power temperature control method Note If the system will be used for the standard application of diverting excess PV power to a hot w...
Страница 43: ...dary unit Surplus PV power will be available to the secondary unit if the primary load reaches maximum power without consuming all of the available surplus PV power or if the set temperature of the he...
Страница 44: ...roller Primary Secondary Mode 2 power sensors and 2 Apollo GEM controllers Primary takes priority Note for wireless systems only one power sensor and transmitter is required Load Share Mode 2 power se...
Страница 45: ...re connected to output 1 falls below the set temperature the system reverts to using output 1 for optimising until the set temperature is reached again 2 THEN 1 Output 2 is used for PV power optimisin...
Страница 46: ...Stat Sensor None Output Options when output mode is Variable Load Power Threshold Setting 100W 16000W Temperature Control T Stat Sensor None Mode Variable Threshold Tmr Only Output Options when output...
Страница 47: ...put Use this setting if the output is connected to a contactor or a non heating appliance Threshold Mode Options Load Power Set to the maximum load power and is the export power threshold used to turn...
Страница 48: ...e set temperature is reached Output 2 then operates in Threshold mode and will divert full power to the load once the programmed export threshold is reached Once threshold control mode has started on...
Страница 49: ...r output 1 has been turned on to reach the programmed threshold of output 2 then output 2 will also turn on fully Once both outputs are active and the export power level becomes insufficient to suppor...
Страница 50: ...pe the probe can be inserted directly into the insulation about half to 2 thirds the way up the cylinder and at an angle of about 30o from vertical Push the probe right into the foam insulation until...
Страница 51: ...the company s discretion the faulty product Exceptions This Warranty will not apply Unless the Apollo GEM Product has been installed by a competent and suitably qualified person according to the inst...
Страница 52: ...of installation 4 Detailed description of the problem 5 A copy of the original supply or installation invoice If the company considers that the warranty claim is valid under the terms of this warranty...