To record at a higher resolution sample rate:

1) Create a Pro Tools session whose sample rate is half the desired rate (i.e., create a 44.1kHz 

session to record 88.2kHz audio.

2) Once the Apogee interface has recognized the sample rate of the session, manually set it to the 

desired high resolution sample rate. When using more than one Apogee interface, the Slave 
interfaces must be clocked from the Master Word Clock Output. 

3) For every track of high resolution audio desired, create a 

stereo

 track in the session. Routing of 

audio is as depicted below:

4) Keep in mind that it’s possible to run one interface at a lower sample rate (for example to play back 

tracks), and a second interface at a higher sample rate (for example to record an analog mix of the 
tracks being played back).

Working with ProTools - 

continued

ROSETTA 800 Analog In

Session Tracks 

(and I/O routing)

ROSETTA 800 Analog Out

Input 1

Tracks 1-2

Output 1

Input 2

Tracks 3-4

Output 2

Input 3

Tracks 5-6

Output 3

Input 4

Tracks 7-8

Output 4

Содержание X-Digi-Mix Card

Страница 1: ...X Series Expansion Cards X Digi Mix Card User s Guide v1 0 October 2003...

Страница 2: ......

Страница 3: ...ons One Rosetta 800 Multiple Rosetta 800s Rosetta 800s with Digidesign interfaces Configuring X Digi Mix equipped Interfaces in Pro Tools Settings in Pro Tools Working with Pro Tools Software control...

Страница 4: ......

Страница 5: ...later use 4 Install the two aluminium standoffs in the holes vacated by the screws 5 Install one end of the plastic standoff in the hole adjacent to the connector pins of the X Digi Mix card install...

Страница 6: ...256 times the sample rate signal 3 When an Apogee interface is Master and a Digidesign interface is Slave connect Superclock Out from the X Digi Mix Card to Superclock In on the Digidesign interface 4...

Страница 7: ...ings in the Pro Tools software To clock Slave Apogee interfaces connect a BNC cable from the Master WC OUT to the Slave WC IN and set the Slave interface SAMPLE RATE to EXT and the CLOCK SOURCE to WC...

Страница 8: ...system the Digidesign interfaces should be connected to the remaining cards Connect the X Digi Mix Card Superclock Out to the Digidesign interface s Superclock In and chain Superclock to remaining Dig...

Страница 9: ...Mix Systems Though Digidesign Mix Systems support sample rates up to 48 kHz it s possible to record and play back digital audio at sample rates up to 96kHz on a Mix system with a X Digi Mix equipped...

Страница 10: ...be clocked from the Master Word Clock Output 3 For every track of high resolution audio desired create a stereo track in the session Routing of audio is as depicted below 4 Keep in mind that it s poss...

Страница 11: ......

Страница 12: ...X Digi Mix Card v 1 0 October 2003 Text conceived and delivered by Roger Robindore Graphics and product illustration by Sean McArthur Photos by Bryan Walsh...

Отзывы: