Apogee SQ-512 Скачать руководство пользователя страница 14

Yield Photon Flux Density (YPFD) Measurements 

Photosynthesis in plants does not respond equally to all photons. Relative quantum yield (plant photosynthetic 
efficiency) is dependent on wavelength (green line in figure below) (McCree, 1972a; Inada, 1976). This is due to the 
combination of spectral absorptivity of plant leaves (absorptivity is higher for blue and red photons than green 
photons) and absorption by non-photosynthetic pigments. As a result, photons in the wavelength range of 
approximately 600-630 nm are the most efficient. 

One potential definition of PAR is weighting photon flux density in units of 

mol m

-2

 s

-1

 at each wavelength 

between 300 and 800 nm by measured relative quantum yield and summing the result. This is defined as yield 
photon flux density (YPFD, units of 

mol m

-2

 s

-1

) (Sager et al., 1988). There are uncertainties and challenges 

associated with this definition of PAR. Measurements used to generate the relative quantum yield data were made 
on single leaves under low radiation levels and at short time scales (McCree, 1972a; Inada, 1976). Whole plants 
and plant canopies typically have multiple leaf layers and are generally grown in the field or greenhouse over the 
course of an entire growing season. Thus, actual conditions plants are subject to are likely different than those the 
single leaves were in when measurements were made by McCree (1972a) and Inada (1976). In addition, relative 
quantum yield shown in the figure above is the mean from twenty-two species grown in the field (McCree, 1972a). 
Mean relative quantum yield for the same species grown in growth chambers was similar, but there were 
differences, particularly at shorter wavelengths (less than 450 nm). There was also some variability between 
species (McCree, 1972a; Inada, 1976). 

McCree (1972b) found that equally weighting all photons between 400 and 700 nm and summing the result, 
defined as photosynthetic photon flux density (PPFD, in units of 

mol m

-2

 s

-1

), was well correlated to 

photosynthesis, and very similar to correlation between YPFD and photosynthesis. As a matter of practicality, PPFD 
is a simpler definition of PAR. At the same time as McCree’s work, others had proposed PPFD as an accurate 
measure of PAR and built sensors that approximated the PPFD weighting factors (Biggs et al., 1971; Federer and 
Tanner, 1966). Correlation between PPFD and YPFD measurements for several radiation sources is very high (figure 
below), as an approxismation, YPFD = 0.9PPFD. As a result, almost universally PAR is defined as PPFD rather than 
YPFD, although YPFD has been used in some studies. The only radiation sources shown (figure below) that don’t 
fall on the regression line are the high pressure sodium (HPS) lamp, reflection from a plant canopy, and 
transmission below a plant canopy. A large fraction of radiation from HPS lamps is in the red range of wavelengths 
where the YPFD weighting factors (measured relative quantum yield) are at or near one. The factor for converting 
PPFD to YPFD for HPS lamps is 0.95, rather than 0.90. The factor for converting PPFD to YPFD for reflected and 
transmitted photons is 1.00. 

 

Defined plant response to 
photons (black line, weighting 
factors used to calculate PPFD), 
measured plant response to 
photons (green line, weighting 
factors used to calculate YPFD), 
and SQ-500 series quantum 
sensor response to photons 
(sensor spectral response). 

Содержание SQ-512

Страница 1: ...TS INC 721 WEST 1800 NORTH LOGAN UTAH 84321 USA TEL 435 792 4700 FAX 435 787 8268 WEB APOGEEINSTRUMENTS COM Copyright 2020 Apogee Instruments Inc OWNER S MANUAL QUANTUM SENSOR Models SQ 512 and SQ 515...

Страница 2: ...of Compliance 3 Introduction 4 Sensor Models 5 Specifications 6 Deployment and Installation 9 Cable Connectors 10 Operation and Measurement 10 Maintenance and Recalibration 17 Troubleshooting and Cus...

Страница 3: ...lectrical and electronic products with respect to the restriction of hazardous substances Please be advised that based on the information available to us from our raw material suppliers the products m...

Страница 4: ...e is not a universal definition of the term flux Flux is sometimes defined as per unit area per unit time and sometimes defined as per unit time only PPFD is used in this manual Sensors that measure P...

Страница 5: ...3636 SQ 512 3717 SQ 515 and above Sensor model number and serial number are located on the bottom of the sensor If you need the manufacturing date of your sensor please contact Apogee Instruments wit...

Страница 6: ...Field of View 180 Spectral Range 389 to 692 nm 5 nm wavelengths where response is greater than 50 Spectral Selectivity Less than 10 from 412 to 682 5 nm see Spectral Response below Directional Cosine...

Страница 7: ...on which was measured with a spectroradiometer Mean temperature response of ten SQ 500 series quantum sensors errors bars represent two standard deviations above and below mean Temperature response me...

Страница 8: ...quantum sensors from the mean of replicate reference quantum sensors LI COR models LI 190 and LI 190R Kipp Zonen model PQS 1 Data were also collected in the laboratory using a reference lamp and posit...

Страница 9: ...on a cross arm an Apogee Instruments model AM 110 mounting bracket is recommended To minimize azimuth error the sensor should be mounted with the cable pointing toward true north in the northern hemi...

Страница 10: ...please contact Apogee directly to ensure ordering the proper pigtail configuration Alignment When reconnecting a sensor arrows on the connector jacket and an aligning notch ensure proper orientation D...

Страница 11: ...damage DO NOT connect the sensor to a power source greater than 24 VDC VERY IMPORTANT Apogee changed all wiring colors of our bare lead sensors in March 2018 in conjunction with the release of inline...

Страница 12: ...put Signal mV PPFD mol m 2 s 1 0 8 2500 2000 Example of PPFD measurement with an Apogee quantum sensor Full sunlight yields a PPFD on a horizontal plane at the Earth s surface of approximately 2000 mo...

Страница 13: ...ic lamps cool white fluorescent metal halide high pressure sodium but larger errors for different mixtures of light emitting diodes LEDs for the SQ 100 series sensors Spectral errors for the SQ 500 se...

Страница 14: ...grown in growth chambers was similar but there were differences particularly at shorter wavelengths less than 450 nm There was also some variability between species McCree 1972a Inada 1976 McCree 1972...

Страница 15: ...M D Clegg 1971 Photosynthesis light sensor and meter Ecology 52 125 131 Federer C A and C B Tanner 1966 Sensors for measuring light available for photosynthesis Ecology 47 654 657 Inada K 1976 Action...

Страница 16: ...actors can be derived by making measurements in air and at multiple water depths at a constant distance from a lamp in a controlled laboratory setting Apogee SQ 500 series quantum sensors have an imme...

Страница 17: ...every two years although you can often wait longer according to your particular tolerances To determine if a specific sensor needs recalibration the Clear Sky Calculator www clearskycalculator com web...

Страница 18: ...s are available one for quantum sensors PPFD and one for pyranometers total shortwave radiation Clear Sky Calculator for quantum sensors Site data are input in blue cells in middle of page and an esti...

Страница 19: ...nloads Zero Offset Error With the use of certain dataloggers it is possible for to measure a non zero voltage zero offset when the sensor output should be zero no photons incident on diffuser This off...

Страница 20: ...or to other units but it requires spectral output of the radiation source of interest Conversion factors for common radiation sources can be found in the Knowledge Base on the Apogee website http www...

Страница 21: ...factory The warranty does not cover equipment that has been damaged due to the following conditions 1 Improper installation or abuse 2 Operation of the instrument outside of its specified operating r...

Страница 22: ...nship Apogee Instruments will repair or replace the items free of charge If it is determined that your product is not covered under warranty you will be informed and given an estimated repair replacem...

Отзывы: