Apogee Instruments SQ-620 Скачать руководство пользователя страница 6

SPECIFICATIONS 

 

Calibration Traceability 

Apogee Instruments SQ-600 series PFD sensors are calibrated through side-by-side comparison to the mean of four 
transfer standard PFD sensors under a reference lamp. The transfer standard PFD sensors are recalibrated with a 
quartz halogen lamp traceable to the National Institute of Standards and Technology (NIST). 

 

SQ-620-SS 

Power Supply 

Self-powered

 

Sensitivity 

0.05 mV per µmol m

-2

 s

-1 

Calibration Factor 

20 µmol m

-2 

s

-1

 per mV 

Calibration Uncertainty 

± 5 % (see Calibration Traceability below) 

Measurement Range 

0 to 4000 µmol m

-2

 s

-1

 

Measurement 
Repeatability 

Less than 0.5 % 

Calibrated Output Range 

0 to 200 mV 

Long-term Drift  
(Non-stability) 

Less than 2 % per year 

Non-linearity 

Less than 1 % (up to 4000 µmol m

-2

 s

-1

Response Time 

Less than 1 ms 

Field of View 

180° 

Spectral Range 

340 to 1040 nm ± 5 nm (wavelengths where response is greater than 50 %; see Spectral 

Response below) 

Directional (Cosine) 
Response 

± 2 % at 45° zenith angle, ± 5 % at 75° zenith angle (see Directional Response below) 

Azimuth Error 

Less than 0.5 % 

Tilt Error 

Less than 0.5 % 

Temperature Response 

-0.11 ± 0.04 % per C 

Uncertainty in Daily Total 

Less than 5 % 

Housing 

Anodized aluminum body with acrylic diffuser 

IP Rating 

IP68 

Operating Environment 

-40 to 70 C; 0 to 100 % relative humidity; can be submerged in water up to depths of 30 m 

Dimensions 

30.5 mm diameter, 37 mm height 

Mass (with 5 m of cable) 

140 g 

Cable 

5 m of two conductor, shielded, twisted-pair wire; TPR jacket; pigtail lead wires; stainless steel 

(316), M8 connector located 25 cm from sensor head 

Warranty 

4 years against defects in materials and workmanship 

Содержание SQ-620

Страница 1: ...NTS INC 721 WEST 1800 NORTH LOGAN UTAH 84321 USA TEL 435 792 4700 FAX 435 787 8268 WEB APOGEEINSTRUMENTS COM Copyright 2020 Apogee Instruments Inc OWNER S MANUAL EXTENDED RANGE PFD SENSOR Models SQ 620 Rev 28 Oct 2020 ...

Страница 2: ...te of Compliance 3 Introduction 4 Sensor Models 5 Specifications 6 Deployment and Installation 8 Cable Connectors 9 Operation and Measurement 9 Maintenance and Recalibration 12 Troubleshooting and Customer Support 13 Return and Warranty Policy 14 ...

Страница 3: ...of electrical and electronic products with respect to the restriction of hazardous substances Please be advised that based on the information available to us from our raw material suppliers the products manufactured by us do not contain as intentional additives any of the restricted materials including lead see note below mercury cadmium hexavalent chromium polybrominated biphenyls PBB polybromina...

Страница 4: ...tum sensor Typical applications of traditional quantum sensors include incoming PPFD measurement over plant canopies in outdoor environments or in greenhouses and growth chambers and reflected or under canopy transmitted PPFD measurement in the same environments The Extended Range PFD Sensor detailed in this manual uses a detector that is sensitive to radiation up to about 1100 nm well beyond the ...

Страница 5: ... respective manuals Model Signal SQ 620 Self powered SQ 622 0 2 5 V SQ 624 4 20 mA SQ 625 0 5 V SQ 626 USB SQ 627 SDI 12 SQ 628 Modbus Sensor model number and serial number are located on the bottom of the sensor If the manufacturing date of a specific sensor is required please contact Apogee Instruments with the serial number of the sensor ...

Страница 6: ...ear Non linearity Less than 1 up to 4000 µmol m 2 s 1 Response Time Less than 1 ms Field of View 180 Spectral Range 340 to 1040 nm 5 nm wavelengths where response is greater than 50 see Spectral Response below Directional Cosine Response 2 at 45 zenith angle 5 at 75 zenith angle see Directional Response below Azimuth Error Less than 0 5 Tilt Error Less than 0 5 Temperature Response 0 11 0 04 per C...

Страница 7: ... respectively Mean spectral response measurements of six replicate Apogee SQ 600 series Extended Range PFD Sensors Spectral response measurements were made at 10 nm increments across a wavelength range of 300 to 1100 nm in a monochromator with an attached electric light source Measured spectral data from each PFD sensor were normalized by the measured spectral response of the monochromator electri...

Страница 8: ...unted with the cable pointing toward true north in the northern hemisphere or true south in the southern hemisphere Azimuth error is typically less than 0 5 but it is easy to minimize by proper cable orientation In addition to orienting the cable to point toward the nearest pole the sensor should also be mounted such that obstructions e g weather station tripod tower or other instrumentation do no...

Страница 9: ...ease contact Apogee directly to ensure ordering the proper pigtail configuration Alignment When reconnecting a sensor arrows on the connector jacket and an aligning notch ensure proper orientation Disconnection for extended periods When disconnecting the sensor for an extended period of time from a station protect the remaining half of the connector still on the station from water and dirt with el...

Страница 10: ...f approximately 0 200 mV is required to cover the photon flux density range the sensor is capable of measuring In order to maximize the measurement resolution and signal to noise ratio the signal input range of the measurement device should closely match the output range of the PFD sensor Wiring for SQ 620 White Positive signal from sensor Black Negative signal from sensor Clear Shield Ground ...

Страница 11: ...µmol m 2 s 1 per mV Sensor Output Signal mV Photon Flux Density µmol m 2 s 1 20 50 1000 Example of photon flux density measurement with an Apogee model SQ 620 Extended Range PFD Sensor The LED in this example Full yields a photon flux density on a horizontal plane of 1000 µmol m 2 s 1 This yields an output signal of 50 mV This signal is converted to photon flux density by multiplying by the calibr...

Страница 12: ...ation water Apogee Instruments upward looking sensors have a domed diffuser and housing for improved self cleaning from rainfall but active cleaning may be necessary Dust or organic deposits are best removed using water or window cleaner and a soft cloth or cotton swab Salt deposits should be dissolved with vinegar and removed with a cloth or cotton swab Salt deposits cannot be removed with solven...

Страница 13: ...sitivity of 0 05 mV per µmol m 2 s 1 Thus a compatible measurement device e g datalogger or controller should have resolution of at least 0 05 mV in order to provide photon flux density resolution of 1 µmol m 2 s 1 and resolution of at least 0 005 mV in order provide photon flux density resolution of 0 1 µmol m 2 s 1 An example datalogger program for Campbell Scientific dataloggers can be found on...

Страница 14: ...r factory The warranty does not cover equipment that has been damaged due to the following conditions 1 Improper installation or abuse 2 Operation of the instrument outside of its specified operating range 3 Natural occurrences such as lightning fire etc 4 Unauthorized modification 5 Improper or unauthorized repair Please note that nominal accuracy drift is normal over time Routine recalibration o...

Страница 15: ...anship Apogee Instruments will repair or replace the items free of charge If it is determined that your product is not covered under warranty you will be informed and given an estimated repair replacement cost PRODUCTS BEYOND THE WARRANTY PERIOD For issues with sensors beyond the warranty period please contact Apogee at techsupport apogeeinstruments com to discuss repair or replacement options OTH...

Отзывы: