![Apogee Instruments SP-722-SS Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/apogee-instruments/sp-722-ss/sp-722-ss_operators-manual_2954262011.webp)
Read only registers (function code 0x3).
Float Registers
0
1
Incident calibrated output watts
2
3
Reflected calibrated output watts
4
5
Incident detector millivolts
6
7
Reflected detector millivolts
8
9
Albedo (reflected/incident)
10
11
Reserved for future use
12
13
"device status
(1 means device is busy, 0 otherwise)"
14
15
firmware version
Integer Registers
44
Incident calibrated output watts
(shifted one decimal point to the left)
45
Reflected calibrated output watts
(shifted one decimal point to the left)
46
Incident detector millivolts
(shifted three decimal points to the left)
47
Reflected detector millivolts
(shifted three decimal points to the left)
48
Albedo (reflected/incident)
(shifted one decimal point to the left)
49
Reserved for future use
50
device status
(1 means device is busy, 0 otherwise)
51
firmware version
(shifted one decimal point to the left)