Aplisens AS-dP Скачать руководство пользователя страница 3

Symbols used 

Symbol 

Description 

 

Warning to proceed strictly in accordance with the information contained in the doc-
umentation in order to ensure the safety and full functionality of the device. 

 

Information particularly useful during installation and operation of the device. 

 

Information on disposal of used equipment. 

 

BASIC REQUIREMENTS AND SAFE USE 

 

The manufacturer will not be liable for damage resulting from incorrect installation, 
failure to maintain a suitable technical condition of the device or use of the device 
other than for its intended purpose.  

Installation should be carried out by qualified staff having the required authorizations 
to install electrical and I&C equipment. The installer  is responsible for performing 
the installation in accordance with manual as well as with the electromagnetic com-
patibility and safety regulations and standards applicable to the type of installation.  

In systems with I&C equipment, in case of leakage, there is a danger to staff due to 
the  medium  under  pressure.  All  safety  and  protection  requirements  must  be  ob-
served during installation, operation and inspections.  

If a malfunction occurs, the device should be disconnected and handed over to the 
manufacturer for repair. 

 

 

 

In order to minimize the risk of malfunction and associated risks to staff, the device 
is not to be installed or used in particularly unfavourable conditions, where the fol-
lowing hazards occur:  

  possible mechanical impacts, excessive shocks and vibration; 

  excessive temperature fluctuation; 

  water vapour condensation, dusting, icing. 

 
Changes made to the manufacturing of products may be introduced before the paper version of the 
manual  is  updated.  The  up-to-

date  manuals  are  available  on  the  manufacturer’s  website: 

www.aplisens.com

.

Содержание AS-dP

Страница 1: ...UAL DIFFERENTIAL PRESSURE TRANSMITTER AS dP EN IO AS dP NOVEMBER 2021 Revision 01 A 001 APLISENS S A 03 192 Warsaw Morelowa 7 St tel 48 22 814 07 77 fax 48 22 814 07 78 www aplisens com e mail export aplisens com ...

Страница 2: ...ies the transmitter and provides quick access to the following documentation on the manufacturer s website user s manual declarations of conformity and copies of certificates AS dP ID 0048 0001 0000 0000 0000 0000 0001 90 https www aplisens pl ID 004800010000000000000000000190 ...

Страница 3: ...al as well as with the electromagnetic com patibility and safety regulations and standards applicable to the type of installation In systems with I C equipment in case of leakage there is a danger to staff due to the medium under pressure All safety and protection requirements must be ob served during installation operation and inspections If a malfunction occurs the device should be disconnected ...

Страница 4: ...Transmitter identification 6 5 3 CE mark declaration of conformity 6 6 INSTALLATION AND CONNECTION 7 6 1 General recommendation 7 6 2 Connection with PD connector 7 6 3 Earthing 7 7 POWER SUPPLY 8 8 OPERATION 8 8 1 Setting of measurement range width and zero point 8 9 MAINTENANCE 8 9 1 Periodic inspections 8 9 2 Cleaning washing 8 9 2 1 Diaphragm cleaning 9 9 3 Repair 9 9 4 Returns 9 10 SCRAPPING ...

Страница 5: ...s operated in a manner not consistent with its intended purpose before installing or disassembling the device it is absolutely necessary to disconnect it from the power source no repairs or alterations to the transmitter electronic system are permitted Assessment of damages and possible repair may only be performed by the manufacturer or authorized representative do not use instruments if damaged ...

Страница 6: ...een tested and has left the factory in a condition that is safe for operation The device complies with the applicable standards and regulations listed in the EU Declaration of Conformity and has CE marking on nameplate Logo and name of manufacturer CE mark Manufacturer s address QR code Transmitter electrical and process connection type Transmitter model ID Transmitter serial number Measuring rang...

Страница 7: ...m of an eave loop in order to prevent the condensate from flowing towards the gland Connect the wires according to the marking on the transmitter and Table 2 depending on the version A correctly assem bled PD connection should have the following tightened the gland nut the nut of the connection to the steel case and the screw connecting both parts of the connection Table 2 Electrical connection of...

Страница 8: ... measuring range and bring the output signal to 4 mA 0 V by turning the zero potentiometer knob turning it clockwise increases the output signal After zeroing set the pressure equal to the upper range limit and use the range potentiometer to bring the output current voltage to 20 mA 10 V Check zero again and repeat the setting if necessary Attention The user by means of potentiometers has the poss...

Страница 9: ...facturer or an authorized representa tive 9 4 Returns In the following cases the transmitter should be returned directly to the manufacturer need for repair need for factory calibration replacement of improperly selected shipped transmitter 10 SCRAPPING DISPOSAL Worn or damaged devices shall be scrapped in accordance with WEEE Directive 2012 19 EU on waste electrical and electronic equipment or re...

Отзывы: