OWNER'S    MANUAL

Split Air Conditioner

future reference.

 

attentively before starting up the unit and keep it carefully for

AM2O-51HPDC1
AM4O-81HPDC1

ALPICAIR AIR CONDITIONERS

Thank you for choosing ALPICAIR air conditioner

s.

Please read this manual

66129909219

Содержание AM2O-51HPDC1

Страница 1: ... Conditioner future reference attentively before starting up the unit and keep it carefully for AM2O 51HPDC1 AM4O 81HPDC1 ALPICAIR AIR CONDITIONERS Thank you for choosing ALPICAIR air conditioners Please read this manual 66129909219 ...

Страница 2: ......

Страница 3: ...ity And Range The Instructions Before Use Name of Parts Outdoor Unit Working Temperature Range GENERAL INSTALLER INFORMATION Please read this owner s manual carefully before Only use the air conditioner as instructed in this booklet These instructions are not intended to cover every possible condition and situation As with any electrical household appliance common sense and caution are therefore a...

Страница 4: ...e special circuit that with air switch protection and assure it has enough capacity The unit will be turned on or off according to your requirement automatically please do not turn on or turn off the unit frequently otherwise disadvantage effect may be caused to the unit Rated voltage of this airconditioner 220 240V 50Hz The compressor will vibrate sharply if the voltage is too low resulting in da...

Страница 5: ...must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard OUTDOOR UNIT No Description 1 Air outlet grille 2 Valve 1 2 1 2 3 Note the above figures are only intended to be a simple diagram of the appliance and may not correspond to the appearance of the units that have been purchased GENERAL INFORMATION Warning Be sure to cut off the power ...

Страница 6: ...RM ATION P L H Minimum power cord section 40 g mm mm mm L P H 4 0 Fuse or air switch 2200 890 362 700 MODE 220 240V 50Hz mm2 Refrigerant gas R410A P L H Minimum power cord section 25 2 5 g mm mm mm L P H Fuse or air switch 1400 818 378 596 MODE Electricity supply Electrical data Electrical data Electricity supply 220 240V 50Hz mm2 Refrigerant gas R410A Size and clearance Size and clearance c AM2O ...

Страница 7: ... at the right side plate of the outdoor unit one screw the connection The fitting line distributing must be Wiring should meet that of indoor unit Fix power connection wire by wire clamp Ensure wire has been fixed well Install the handle cable with the terminal at the row of connection and fix consistent with the indoor unit terminal of line bank ELECTRICAL CONNECTIONS INSTALLER The connection pip...

Страница 8: ...with the indoor unit terminal of line bank ELECTRICAL CONNECTIONS INSTALLER The conne ct ion pipes and the connectiong wirings of the unit A unit B unit C and unit D must be corresponding to each other respective The applian ce shall be in st alled in accordance wit h national wiring regulations Do not install the outdoor unit where it is exposed to the sunlight HANDLING After havingremoved the pa...

Страница 9: ...top the vacuum pump 6 Open the 2 way valve by 1 4 turn and then close it after 10 seconds Check all the joints for leaks using liquid soap or an electronic leak device 7 Turn the body of the 2 way and 3 way valves Discon nect the vacuum pump hose 8 Replace and tighten all the caps on the valves BLEEDING INSTALLER INDOOR UNIT Install the drain fitting and the drain hose for model with heat pump onl...

Страница 10: ...o unprofessional installation When picking up and moving the units you must be guidedby trained and qualified person Ensure that the recommendedspace is left ar ound the a ppliance 30cm Space to the cover or above 30cm 50cm 200cm or more Space to the cover Air inlet side or above or above Space to the wall Air outlet side or above 50cm 30cm Space to the cover or above 30cm 50cm 200cm or more Space...

Страница 11: ...ecified on the nameplate The unit may bread down or the components may be burned out Are the lines and pipelines correctly installed The unit may bread down or the components may be burned out Has the unit been safely grounded Risk of electrical leakage Are the models of lines in conformity with requirements The unit may bread down or the components may be burned out Are there any obstacles near t...