background image

 

  

 

 

 

 

 

 

 

T25 Tube Compressor 

 

 

 

OPERATOR’S MANUAL 

 

 

Written for Automated Processes Incorporated 

by Dan Pfeifer 

Rev. 21-04-26

 

 
 
 
 

 

 

 

 

 

Содержание T25

Страница 1: ...T25 Tube Compressor OPERATOR S MANUAL Written for Automated Processes Incorporated by Dan Pfeifer Rev 21 04 26 ...

Страница 2: ...3 IN out Switch 8 5 4 Bypass Switch 8 5 5 Stereo Link Switch 8 6 0 Level Indication 9 6 1 Gain Reduction Meter Peak Indicator 9 6 2 VU Meter 9 7 0 Tube Vent Window 9 8 0 Power Switch Rear Panel Connections 10 8 1 Power Switch 10 8 2 Rear Panel 10 8 2 1 Audio Connections 10 8 2 2 AC Power 10 APPENDIX 11 A1 Technical Specifications 12 A2 Block Diagram 12 A3 Recall Chart 13 A4 User Accessible Mainten...

Страница 3: ...his manual is organized in sections that correspond to the front panel controls and rear panel interface Legend UPPER CASE BOLD POTS CONTROLS SWITCHES BUTTONS UPPER CASE REAR PANEL CONNECTIONS Manual Revision History YY MM DD format Original 21 04 26 Revised Dan Pfeifer is a Professor of Recording Industry at Middle Tennessee State University ...

Страница 4: ...w for proper power supply cooling Do not touch the rear panel surface for an extended period of time when the unit is powered on 11 Do not install near any heat sources such as radiators heat registers stoves or other devices that produce heat 12 Do not defeat the safety purpose of the polarized or grounding type AC plug 13 Protect the AC power cord from being walked on or pinched 14 Use only atta...

Страница 5: ...me switch 11 step release time switch 4 fixed ratios 31 step input threshold control 31 step output make up gain control Detented controls for accurate recall Patented THRUST filter for low frequency dependent side chain control D S feature provides high frequency dependent side chain control for de essing Link switch for stereo operation 10 segment LED gain reduction meter LED peak indicator Vint...

Страница 6: ...have a useful but conservative effect on the signal After the unit has been powered on and warmed up Set the following knobs to the 12 00 position o ATTACK o RELEASE o IN THRESHOLD o OUT MAKE UP Set RATIO to 2 1 Engage the IN switch Disengage the D S THRUST BYP and LINK switches These settings will provide a good starting place for additional tweaking to achieve the desired sound NOTE The T25 is a...

Страница 7: ...e input level threshold o Sets the level at which compression begins threshold Out MAKE UP Output Make up Gain Sets the compressor output level make up gain D S Toggles to activate the de esser function o Accentuates compression of high frequency content THRUST Toggles to activate the patented THRUST filter circuit o Reduces heavy low frequency content in the detection path IN Toggles to switch co...

Страница 8: ...e 11 step switch 4 3 Ratio RATIO Simultaneously sets the compression ratio input vs output and adjusts the threshold level for optimal settings Four fixed ratios 2 1 4 1 8 1 and 20 1 4 step switch Compression with high ratios is generally considered to be limiting 4 4 Input Level Threshold IN THRESH Input Threshold Sets the input level threshold Determines the level at which compression begins dBu...

Страница 9: ...cade filter before the RMS detector Illuminates when engaged The patented THRUST circuit has been used for many years in the famed API 2500 Stereo Compressor ATI Paragon and Paragon II consoles as well as the Pro6 Input Strip This circuit places a filter in front of the RMS detector with a slope of 10dB per decade 3dB 8va which is the inverse of the pink noise energy curve In acoustics the pink no...

Страница 10: ...llowing audio to pass directly through the device This allows the T25 to be powered off when not in use in order to prolong tube life 5 5 Stereo Link Switch The channels 1 and 2 of the T25 Tube Compressor function can be linked together for stereo operation This will prevent center image shifting caused by differing amounts of gain reduction on each channel when compressing correlated stereo signa...

Страница 11: ...ccurate indication of gain reduction PEAK Indicates when output level reaches or exceeds 18dBu Red LED 6 2 VU Meter OUTPUT LEVEL VU Indicates the signal level at the OUTPUT connector 0VU is 4dBu factory setting 0VU 14dBu option with internal jumper adjustment Vintage look Backlit NOTE The T25 VU meter cannot display gain reduction 7 0 Tube Vent Window The T25 Tube Compressor is equipped with metal...

Страница 12: ... both channels connections as well as AC power connection voltage selection and fuse 8 2 1 Audio Connections Each audio channel Left and Right has an INPUT and OUTPUT connection IMPORTANT NOTE The XLR and INPUT connectors are wired together so use only one INPUT connection a time IMPORTANT NOTE Care should be taken not to short the outputs as damage will occur to the output stage 8 2 2 AC Power Th...

Страница 13: ...T25 Tube Compressor API Select 11 APPENDIX A1 Specifications A2 Block Diagram A3 Recall Chart A4 User Accessible Maintenance A5 API Limited Warranty and Service ...

Страница 14: ...imum output level 24dBu Frequency Response 20Hz 40kHz 0dB 1dB Ratios 2 1 4 1 8 1 20 1 switchable Attack Times 20µs 0 8ms Release Times 50ms to 1 2s Total Gain 40dB IN OUT both fully CW SNR 90dB Power Consumption 45W Size 19 x 3 5 x 12 Deep Size Boxed for Shipping 21 x 9 x 15 Actual Weight 14 lbs Shipping Weight 17 lbs A2 Block Diagram ...

Страница 15: ...T25 Tube Compressor API Select 13 A3 Recall Chart ...

Страница 16: ...nit has been unplugged for at least 5 minutes before opening the chassis Four screws on sides remove the lid and allow access to the printed circuit board No user tube bias adjustments A4 2 VU Meter Level Jumper A marked internal jumper selects between 0VU 4dBu and 0VU 14dBu for the OUTPUT LEVEL VU meter one per channel Make sure power switch is off Make sure the unit has been unplugged for at lea...

Страница 17: ...ntain and service your product f The below steps are the best way to initiate the repair process or to submit a parts order request Repair procedure 1 Fill out a Return Authorization RA form at service apiaudio com 2 Wait to receive an e mail from API Audio with an RA 3 Use the API original box to package the unit Write the RA large and legibly on the box if the RA is not clearly visible on the bo...

Страница 18: ... 2021 8301 Patuxent Range Road Jessup MD 20794 USA 301 776 7879 http www apiaudio com ...