background image

RST-5003 Control Module
Installation Guide

Web Enabled Series

R

APG

Automation Products Group, Inc.

1025 W 1700 N Logan, UT 84321

www.apgsensors.com | phone: 888-525-7300 | email: [email protected]

Thank You

Thanks for purchasing a RST-5003 control module from us! We appreciate your business and 

your trust. Please take a moment to familiarize yourself with the product and this manual before 

installation. If you have any questions, at any time, don’t hesitate to call us at 888-525-7300.

APG warrants its products to be free from defects of material and workmanship and will, without 

charge, replace or repair any equipment found defective upon inspection at its factory, provided 

the equipment has been returned, transportation prepaid, within 24 months from date of shipment 

from factory.   

THE FOREGOING WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES NOT 

EXPRESSLY SET FORTH HEREIN, WHETHER EXPRESSED OR IMPLIED BY OPERATION OF LAW OR  

OTHERWISE INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY 

OR FITNESS FOR A PARTICULAR PURPOSE.

No representation or warranty, express or implied, made by any sales representative, distributor, 

or other agent or representative of APG which is not specifically set  forth herein shall be binding 

upon APG. APG shall not be liable for any incidental or consequential damages, losses or expenses 

directly or indirectly arising from the sale, handling, improper application or use of the goods or 

from any other cause relating thereto and APG’s liability hereunder, in any case, is expressly limited 

to the repair or replacement (at APG’s option) of goods.

Warranty is specifically at the factory. Any on site service will be provided at the sole expense of the 

Purchaser at standard field service rates.   

All associated equipment must be protected by properly rated electronic/electrical protection 

devices. APG shall not be liable for any damage due to improper engineering or installation by the 

Purchaser or third parties. Proper installation, operation and maintenance of the product becomes 

the responsibility of the user upon receipt of the product.   

Returns and allowances must be authorized by APG in advance. APG will assign a Return Material 

Authorization (RMA) number which must appear on all related papers and the outside of the 

shipping carton. All returns are subject to the final review by APG. Returns are subject to restocking 

charges as determined by APG’s “Credit Return Policy”.   

1.Description
2. How To Read Your Label
3. Warranty
4. Installation Procedure

5. Dimensions
6. Power Supply Wiring 

Diagrams
7. Modbus System Wiring 

Diagrams

8. Embedded Webpage
9. General Care
10. Repair Information
11. Removal Instructions

Table of Contents

 

4

Installation Procedure

Installing your RST-5003 is easy if you follow a few simple steps:

• 

Connect any 4-20 mA sensor, relays, or switched inputs first.

• 

Connect RST to Ethernet/network

• 

Connect independant 12-28 VDC supply if not using POE.

• 

Connect and set up one Modbus sensor at a time.

Please keep the following limitations in mind:

• 

Up to 10 Modbus sensors can be connected to the RST-5003 in any combination.

• 

Only one 4-20 mA sensor can be connected to the RST-5003.

5

Dimensions

 

NOTE

: Scan the QR code to the below to visit www.apgsensors.com/support.

   

APG Support Website

Part # 122950-0012

Doc #9004245 Rev A

Each label comes with a full model number, a part number, and a serial number. The model 

number for the RST-5003 will look something like this:

The model number correlates with all the configurable options and tells you exactly what you have. 

Compare the model number to the options on the datasheet to identify your exact configuration. 

You can also call us with the model, part, or the serial number and we can help you.

 

SAMPLE

RST-5013

The RST-5003 Web Enabled Control Module offers a wide degree of integrated and flexible remote 

and local control and monitoring for your system. The RST-5003 can control up to ten APG Modbus 

sensors--any combination of level, pressure, magnetostrictive and ultrasonic--along with one 

4-20 mA sensor, and two input or out relay terminals. All readings are available for control and 

monitoring via TCP/IP for local or remote network access. The RST-5003 also had flexible power 

options: it can use either POE or an independent 12-28 VDC power source.

1

Description

2

How To Read Your Label

3

Warranty

2

4

V

B

G

N

D

A

7/8”

4”

4 1/2”

 

IMPORTANT

: Each Modbus sensor must be added to the network individually and 

assigned a unique Sensor Number before the next sensor can be added.

 

NOTE

: If you can control power to each Modbus sensor individually, you can connect 

them all simultaneously, and power them on individually.

6

Power Supply Wiring Diagrams

To Network 

Connection

Input for supply 

voltage when 

using a non-POE 

power source

To 12-28 VDC 

Power Source

2

4

V

4

2

0

G

N

D

G

N

D

RST-5003

External 12-28VDC Power Supply Wiring

POWER

LAN + DC

LAN

To Network Connection

To AC 

power

POE

Power

Injector

Provides 24 VDC

to supply a 4-20 mA 

device when the RST 

is powered via POE.  

2

4

V

4

2

0

G

N

D

G

N

D

RST-5003

NOTE: A POE-enabled

Ethernet switch eliminates

the need for a POE Power

Injector.

POE (Power Over Ethernet) Wiring