Water Pump Control
The het pump controls the water pump if it is connected. The heat pump will start the water pump if the water of the
swimmingpool needs to be heated or cooled (F11). When the heat pump is in stand-by, it will start the water pump every 60
minutes during 5 minutes to check the water temperature. This feature can be modified using parameters F43 and F44.
External alarm
The controller can connect a switching value as external alarm source (Pin 4, 5), (Pin 13, 14), (Pin 14, 15), when the external alarm
occurs, the controller stops, displays the alarm code “A11”, “A12” and “A15” and generates alarm output. External alarm signal has 1
modes (F50, F51, F52):
·
·
3: always closed, unlocked
Probation time
A probation time can be set (F87), the controller can add up the running time after power is on, if the accumulative running
time
is over the probation time, the controller will stop and display the alarm code A99, if you want to eliminate the limit of
probation
time, set the F87 to “OFF”, also you can use the F86 to clear the accumulative running time, and you can try to use it
again. The
parameter F85 can be used to examine the accumulative running time of the controller (hour).
Password
In order to prevent irrespective persons from changing the parameters, you can set a password (F80), and if you have set a pass-
word, the controller will hint you to enter the password after you press the key “M” for 5 seconds, you must enter the correct pass-
word, and then you can set the parameters. If you don’t need the password, you can set F80 to “OFF”. Notice that you must
remember the password, and if you forget the password, you can not enter the set state.
6. START-UP PROCEDURE FOR THE UNIT
Operating requirements for the heat pump
·
The outdoor temperature must be higher than +0 ºC.
·
The heat pump is provided with a defrost thermostat that guarantees the compressor shutdown and the operation of the
defrost system.
·
When washing the filter of the filtering pump, it is OBLIGATORY that the heat pump is turned off.
39
Содержание 60298
Страница 2: ......
Страница 11: ...11 ATTENTION POMPE CHALEUR PacMAGIC fran ais...
Страница 29: ...ATTENTION PacMAGIC HEAT PUMP english 29...
Страница 47: ...ATENCI N BOMBA DE CALOR PacMAGIC espa ol 47...
Страница 65: ...deutsch ACHTUNG 65...
Страница 79: ...ERROR syntaxerror OFFENDING COMMAND ztokenexec_continue STACK filestream...