background image

9

INSTALLATION

ARGHD90SS

instructions provided must install the appliance. The 

manufacturer declines all responsibility for improper 

installation, which may harm persons and animals and 

damage property.

CAUTION

The power supply to the appliance must be switched 

off before any adjustments or maintenance work is 

undertaken.

INSTALLATION OF GAS HOB

WARNING

Good ventilation is required around the appliance for 

easier dissipation of heat and low power consumption.

The gap between the hob and any cooker hood above it 

should be at least 750mm.
The gap between the hob and any adjacent wall cabinet 

above should be at least 450mm.

ELECTRICAL CONNECTION

All installation work must be carried out by a competent 

Before connecting the mains supply ensure that the 

mains voltage corresponds to the voltage on the rating 

plate inside the cooker hood.

WARNING:

THIS APPLIANCE MUST BE EARTHED.

Mains Supply could be connected to the Mains Voltage 

by Direct Connection

WARNING

Make sure the fused spur outlet is 

located in an accessible position.

DIRECT CONNECTION

If the appliance is being connected 

directly to the mains an omnipolar 

circuit-breaker must be installed with a minimum 

opening of 3mm between contacts.
If the cable is damaged or to be replaced, the operation 

dedicated tools to avoid any accidents.
The installer must ensure that the correct electrical 

connection has been made and that it complies with 

wiring diagram.
The cable must not be bent or compressed.
The cable must be checked regularly and replaced by 

authorized technicians only.

ELECTRICAL REQUIREMENTS

Any permanent electrical installation must comply with 

the latest I.E.E. Regulations and local electricity company 

contractor who is on the roll of the National Inspection 

Council for Electrical Installation Contracting (NICEIC) 

should undertake the electrical installation.
Electrical Connection
Before connecting the mains supply ensure that the 

mains voltage corresponds to the voltage on the rating 

plate inside the appliance.

WARNING: 

THIS APPLIANCE MUST BE EARTHED

The appliance is supplied with a 3-core mains cable and 

must be connected to the electricity supply via a double 

pole switch having a 3mm minimum contact gap on each 

connector.

FUSE

USE  A 3 AMP FUSE

DOUBLE POLE SWITCHED

FUSED SPUR OUTLET

ON

75mm

At least
300mm

750mm

At least

300mm

450mm

75mm

At least
300mm

750mm

At least

300mm

450mm

Содержание ARGHD90SS

Страница 1: ...ARGHD90SS USER MANUAL CUSTOMER CARE 0844 800 1128 BUILT IN 90CM STAINLESS STEEL GAS HOB...

Страница 2: ...afety instructions carefully to avoid misuse and hazards Please keep this instruction booklet for future reference and pass it on to any future owners After unpacking the appliance please check that i...

Страница 3: ...s appliance Danger of burns During use the appliance becomes hot Care should be taken to avoid touching heating elements inside the oven WARNING Accessible parts may become hot during use Children sho...

Страница 4: ...y use utensils that are suitable for use in this type of oven ENVIRONMENTAL INFORMATION Waste electrical products should not be disposed of with household waste Please recycle where facilities exist C...

Страница 5: ...ft control dial C Centre control dial D Rear right control dial E Front right control dial YOUR CONTROLS A A Auxiliary burner B Rapid burner C Semi rapid burner D Triple ring burner E Hob F Burner cap...

Страница 6: ...installation THE RIGHT GAS CONNECTION This oven can be use on NATURAL GAS or LPG It is a legal requirement that all gas appliances are Installed Serviced by a competent person in accordance with the...

Страница 7: ...n so that the knob is at MAXIMUM Once the burner is lit keep the knob pressed in for about thermocouple If the burner goes out when the knob is let go repeat the operation CAUTION If there is no elect...

Страница 8: ...ormally commercially available Never use abrasive powders cleaned by simply removing them and washing them with soapy water After drying them well and checking that the holes are not blocked put them...

Страница 9: ...ed directly to the mains an omnipolar circuit breaker must be installed with a minimum opening of 3mm between contacts If the cable is damaged or to be replaced the operation dedicated tools to avoid...

Страница 10: ...following table details the requirements based on the kitchen volume L x W x H in m The above requirements also allow use of a gas oven and grill but if there are any other fuel burning appliances in...

Страница 11: ...CHECK that the mains supply has not been switched off that the fuse in the spur has not blown that the burner components are not excessively soiled as this can lead to ignition problems that the appli...

Страница 12: ...and is in addition to and does not diminish your legal rights EXTENDED PARTS ONLY WARRANTY As testimony to our commitment to you as a valued customer of Apelson Appliances UK Ltd we will offer you an...

Страница 13: ...800 1128 Email uksupport apelson co uk Web www myspareparts co uk SPARES Apelson Appliances UK LTD Phone 0844 800 1128 Email uksupport apelson co uk Web www myspareparts co uk SERVICE AND GUARANTEE Ap...

Страница 14: ......

Страница 15: ......

Страница 16: ...APELSON APPLIANCES UK LTD 1 EXPRESS WAY OFF CALIFORNIA DRIVE CASTLEFORD WF10 5QJ...

Отзывы: