APART ZONE4 Скачать руководство пользователя страница 6

4

Pre-Amplifiers

Introduction

Zone 4 professional preamp has 4 stereo line source inputs on RCA 
connectors plus 3 mono mic/line balanced inputs on euroblocks. All 
mic inputs feature individual sensitivity, level and tone control. Mic 
2 and 3 inputs have switchable phantom power. Each mic signal 
can be assigned to any of the 4 available zone outputs.Microphone 
input 1 controls and connectors are available at the rear of the 
unit, featuring a balanced mic input with priority switch and zone 
assign preset dipswitches. If you need more flexibility and ease 
of installation, simply connect our Apart selective paging station 
MICPAT-4 instead, it will override the mic 1 zone assignments. Mic 
2 and 3 inputs can be controlled and assigned via the front panel 
controls. In order to avoid any abuse by the end user, you can hide 
the microphone controls with the supplied cover plate.

Zone 1 to 4 stereo outputs can be individually configured as mono 
or stereo outputs and are available on RCA connectors. Every zone 
has its own line input selector, bass and treble tone control and 
music level control. Every zone also has its own microphone mix 
level control. Music and mic mix can be muted/unmuted manually 
per zone by simply pushing the level knob.

System integrators will be pleased to find a RS232 port at the back, 
allowing full control of the most important system parameters.

If you need to control the zones locally, you can always add a wired 
remote, Apart model ZONE4R to any zone. Wiring is simple, using 
standard RJ45 connectors and CAT5 cable.

Finally there is the IR input port. This port can be used to connect 
our optional PIR-REC infrared receiver. There is no infrared remote 
control available for the ZONE4 unit. We have added the infrared 
codes for those who want to program their universal infrared 
control unit.

Содержание ZONE4

Страница 1: ...ZONE4 Instruction manual...

Страница 2: ......

Страница 3: ...Instruction manual ZONE4 1 ZONE4 Manual...

Страница 4: ...g high sound pressure levels such as this amplifier be protected by hearing protection while installing or operating this unit Read all documentation before operating your equipment Keep all documenta...

Страница 5: ...amplifier or console is turned on or off Power down disconnect units from mains voltage before making connections Do not use the unit near stoves heat registers radiators or other heat producing devi...

Страница 6: ...you can hide the microphone controls with the supplied cover plate Zone 1 to 4 stereo outputs can be individually configured as mono or stereo outputs and are available on RCA connectors Every zone h...

Страница 7: ...ve The paging button s will not mute the music or line signals Mic 1 will be entirely disabled 3 Zone assign dipswitches mic 2 with these dipswitches you can assign the mic 2 signal to zone 1 to 4 4 Z...

Страница 8: ...hown in the display 12 as A b C d 12 Multifunctional 7 segment LED display this display shows the currently selected line input When you change the mic or music level by turning the knobs 15 or 17 the...

Страница 9: ...led 18 18 Mic mix mute led this led lights up when the mic mix in zone 1 is muted by pushing the 17 knob Please note that this will not disable the paging function of the mics in other words if the mi...

Страница 10: ...in your audio signal 4 RS232 connector connect your serial cable here For details refer to the separate serial communication section 5 IR bus input for optional PIR REC infrared receiver Please note...

Страница 11: ...and right connectors 11 Zone 4 output connector on cinch connectors 12 Zone 3 output connector on cinch connectors 13 Zone 2 output connector on cinch connectors 14 Zone 1 output connector on cinch co...

Страница 12: ...this contact mutes the music 25 Mic 1 level control 26 Mic 1 zone assign switch 27 Mic 1 tone control 28 Mic 1 input selector push the switch in out to select the mic connector on euroblock or the MIC...

Страница 13: ...LECT SOURCE C ZONE 1 9MS 04FB 13 SELECT SOURCE D ZONE 1 9MS 04FB 14 MUSIC VOLUME UP ZONE 2 9MS 04FB 8B MUSIC VOLUME DOWN ZONE 2 9MS 04FB 8F MIC VOLUME UP ZONE 2 9MS 04FB 8A MIC VOLUME DOWN ZONE 2 9MS...

Страница 14: ...rce B ZONE 4 9MS 04FB 26 Select source C ZONE 4 9MS 04FB 27 Select source D ZONE 4 9MS 04FB 28 Mute music ZONE1 9MS 04FB 81 Un mute music ZONE1 9MS 04FB 1A Mute mic ZONE1 9MS 04FB 8C Un mute mic ZONE1...

Страница 15: ...4 9MS 04FB 88 Un mute mic ZONE 4 9MS 04FB 2D Disconnect paging on 9MS 04FB 84 Connect paging off 9MS 04FB 2E Source up ZONE 1 9MS 04FB 85 Source up ZONE 2 9MS 04FB 8D Source up ZONE 3 9MS 04FB 95 Sou...

Страница 16: ...requency response 20 HZ 30 kHz S N Ratio 90dB THD 0 02 Crosstalk 75 dB Max nominal gain 5 dB Max output voltage 13 dBV 4 5 V Tone control zone 1 to 4 Bass 75 Hz 10 dB treble 10 kHz 10 dB Line inputs L...

Страница 17: ...mic line 2 and 3 max input level 38 dBV to 1 dBV gain max min CMRR 50 dB S N Ratio 65 dB MIC level 4 mV THD 0 09 Phantom power mic 2 and 3 18 V individually switchable Tone control mic line 1 to 3 Fr...

Страница 18: ...16 Pre Amplifiers Block diagram...

Страница 19: ...Instruction manual ZONE4 17...

Страница 20: ...udioprof nv Industriepark Brechtsebaan 8 bus 1 2900 Schoten Belgium Company names product names and trademarks are property of their respective owners Apart Audio specifications are subject to change...

Отзывы: