Instruction manual
REVAMP1680
11
!!!IMPORTANT!!!
This amplifier relies on convection and active cooling. In normal
situations, overheating will not occur. The unit can be built in a
19” inch rack system, but it is forbidden to block the ventilation
holes provided. Therefore, it is absolutely necessary to allow at least
one free rack space or 44 mm above and beneath the amplifier.
Make sure the ambient temperature is between 0 and 40°C.
Operating the unit beyond its normal limits will result in excessive
internal temperature. Power amplifiers are hard workers, and
their behaviour is similar to human beings. In extreme conditions,
human beings are not able to perform efficiently. This also applies
to amplifiers. It is generally a bad idea to mount multiple heat
generating units such as amplifiers in the same rack. If necessary,
use an additional forced ventilation system in your mounting rack.
The mains fuse is located inside the unit. When the fuse is broken,
replace it with a fuse of the same current and voltage rating:
8 AT/250V for 230 VAC operation or 15 AT/250V for 115 VAC
operation. For qualified personnel only!
This unit has NOT been designed for use in mobile applications,
such as: mobile discobars and DJ setups, mobile PA systems, live
bands, audio rental systems, …
Use it in fixed installations only.