24)   CD stereo input, 500mV: Here you can feed a line level signal.   You have to make your choice with the 

selector at the front (see 12).  Stereo signals will be summed together. 

25)   AUX input, 500mV: Use this stereo RCA input to connect a line level source such as CD player, MD player, 

BGM computer, etc….  You have to make your choice with the selector at the front (see 12).  Stereo signals 

will be summed together.

26)   Line 4, 200mV / Mic 4 input. Use only one of these parallel wired inputs at the time!  To the XLR3 balanced 

input you can connect any microphone using a balanced, two wire shielded cable. (1=earth / 2 =hot / 

3=cold).  For using condenser microphones see 41.  The Microphone 4 input is a XLR3/combo jack, which 

will accept a normal XLR3 male plug or a ¼” TRS phone jack. 

Line 4 is more sensitive than the other line (music) inputs, therefore ideal to connect wireless microphone 

receivers.

27)   Mic 2  Mic 3 XLR inputs. To the XLR balanced input you can connect any microphone using a balanced, 

two wire shielded, cable (1=earth / 2 =hot / 3=cold). 

28)  Mic 1 XLR / DIN5 / Euro block. Use only one of these parallel wired balanced inputs at the time!  See wiring 

diagram at the back.  These three inputs have been wired in parallel with the balanced jack input at the front.  

When you use the APart MICPAT paging microphones, connected directly to the DIN5 input, the signals fed 

into the line inputs are muted automatically while paging. The same kind of connection can be made using 

the euro block connector. To use “vox mute” see 29. 

Phantom power: use condenser microphones see 41

29)   Vox mutes all. When you activate “vox mute” by turning this trimmer clockwise to the desired threshold 

level, the signal of any Mic1 input has priority.  When you don’t need “vox mute”, turn this trimmer fully 

counter-clockwise to the “OFF” position.  

30)   Priority over music contact. By closing the contact of the euro block connector or contacts 4 and 5 of the 

DIN5 connector, the signal of microphone 1 only has priority over the music sources (TUNER, CD and 

AUX).  All other microphones will remain active.  The contact closure of the contacts mentioned can give 

priority to the other microphone inputs as well.  At the same time 24 V DC will be available at terminal 20.  

This is very useful when using up to 4 microphones in supermarkets, etc…

31)   Chime level. When one of the priority contacts are closed a chime can be activated by turning this trimmer 

clockwise to the desired chime level.  When you don’t need a chime, turn this control fully counter-clockwise 

to the “OFF” position.

32)   Emergency / telephone input. Here you can feed the audio source for paging emergency messages, etc..  

This input, at line level, has automatic activation above 200mV and has a line transformer to avoid ground 

loops (useful for telephone). Please use a balanced, shielded line cable.  Connect the HOT signal to +, 

the COLD to  and the shield to G (when connecting the shield only at the MA200R side, you might avoid a 

ground loop, which creates hum and buzz).  This signal is directly fed into the main amplifier. 

No microphones should be connected directly to this input without using a mic to line pre-amplifier.

33)   Emergency / telephone level. With this potentiometer you can set the desired level of the line level signal 

inserted into the priority signal input 32.  This level will not be influenced by the “master” level.

34)   FM antenna. This socket has to be used to connect your 75 ohm FM antenna.  You can use the shipped in-

door “wire” antenna, but to improve the reception, we advise to install an outdoor FM antenna or to connect 

the MA200R to the cable radio network.  

Important notice:  In case you connect to the cable radio network, we recommend a ground isolator HF 

transformer in order to avoid hum (ground loops) or wire only connecting the HOT pin.

35)   AM antenna socket. Here, the shipped indoor AM antenna has to be connected.

36)   Airflow output. This airflow output should be kept free at all times!  To give the fan a longer life time, he only 

starts running when the heatsink reaches a certain temperature. 

Содержание MA200R

Страница 1: ...INFO APART AUDIO COM MANUAL MA200R...

Страница 2: ...ge source such as a battery mains source or power supply regardless of whether the amplifier or console is turned on or off Power down disconnect units from mains voltage before making connections Do...

Страница 3: ...Content 1 APart MA200R Mixing Amplifier 2 Front Panel 3 Rear Panel 4 Tuner Controls 5 Inside Settings 6 Overview Of The MA200 Series 7 How To Deal With 100V Loudspeakers Systems 8 Technical Specificat...

Страница 4: ...nd mutes all other signals except the emer gency input The third level can be activated via a dry contact priority over music and mutes all background music inputs only This contact activates the chim...

Страница 5: ...RS phone jack has been wired in parallel with the other three input options for microphone 1 at the back For satisfying operation use only one of these inputs at the time for microphone 1 Microphone 1...

Страница 6: ...eaker connections Only one at the time should be used unless you are able to calculate a combination which does not overload the amplifier example 100 at 100V for a loud zone in combination with 25 at...

Страница 7: ...the DIN5 connector the signal of microphone 1 only has priority over the music sources TUNER CD and AUX All other microphones will remain active The contact closure of the contacts mentioned can give...

Страница 8: ...rt to scan across the memory presets Each preset will be heard for about three seconds starting from the next preset till you reach the preset you where listening to again To stop this feature press S...

Страница 9: ...hether the power cord has been inserted properly If these two have been checked and still the MA200R remains off the fuse might be blown No sound Check all the wires and loudspeaker selectors At least...

Страница 10: ...ternal switch 4 line inputs 3 level priority system 24V priority output Integrated 2 tone chime adjustable volume 4 output zones Zone 4 Mic music selection Build in dynamic limiter 3 dB Dimensions 88...

Страница 11: ...s on a 100Volt system not even one More technically When your paging amp has a maximum output of 200 watts at 100V this means that the minimum impedance connected should be at least 50 ohm 100x100 200...

Страница 12: ...ED BY PRIORITY VOX Pre Amp 1V EMERGENCY TELEPHONE TRAFO VOLUME INPUT1 VOLUME INPUT2 VOLUME INPUT3 VOLUME INPUT4 VOLUME INPUT5 300mV TUNER OUT L R 500mV CD IN OUT L R 500mV AUX 200mV LINE 4 L R 1 5mV M...

Страница 13: ...ED INDICATORS limiter active red signal 100 yellow signal 25 dB green power on green protection active red ZONE ACTIVE INDICATORS Z1 Z2 and Z3 green LED Z4 music on off orange Z4 paging allowed on off...

Страница 14: ...QUENCY RESPONSE 100Hz 25Khz 1 3 dB MUTE mutes all 40 dB auX input Rca SENSITIVITY 500 MV 6 DB IMPEDANCE 22 K S N AT MAX VOLUME 80 DB FREQUENCY RESPONSE 40HZ 25KHZ 1 3 DB Line 4 Rca SENSITIVITY 200 MV...

Страница 15: ...V tuneR Rca Mono Moh LEVEL 300 mV RecoRD out Rca Mono LEVEL 1 V pRioRity out LEVEL 24 V DC max 1A short circuit protected chiMe 2 tone activated by contact closure euro block DIN5 on off and level se...