APART E-VOL60 Скачать руководство пользователя страница 2

WWW.APART-AUDIO.COM

Volume Control

OUT

IN

-  24V  +

+

-

24V

100V

Microphone

100V

olt

com

com

Amplifier

24Volt Priority output

• MA200

• MA200R

• MA200CDR

• MA125

• PA240P (only 30pcs)

e.g. You can use one of 

these APart amplifiers

to connect up to 50pcs

volume controllers.

TOTAL LOUDSPEAKER POWER : 3 - 60 WATTS MAXIMUM !!!

USE ONLY HIGH IMPEDANCE

100VOLT LOUDSPEAKERS

4-WIRE CONNECTION WITH PRIORITY

•  Keep the inside of the wallbox clear of all wires, this to prevent short circuits between the wires in the wallbox 

and the printed circuit of the volume controller.

•  Don’t use solid copper conductor wires, the screw connectors on the printed circuit board of the volume con-

troller are designed for flexible wires.

• Don’t connect more then one wire in each onboard screw connectors of the volume controller.

• Don’t use force when mounting the volume controller in the wallbox.  

Mounting

What does a priority system do ?

When the volume controller is turned to 0 there is no background-music. (e.g. meeting room, office)

At this moment if there is a microphone call the information is lost.

With the priority system connected, the volume controller is set to maximum volume during the microphone call.

In this way there is no information lost.

To be able to use a priority system you need the following components :

 - Volume controller with priority relay (E-VOL60,E-VOL120)

 - Amplifier with 24Volts priority output contact (24Volts / 1A : you can connect up to 60pcs of volume controllers)

 - 4-wire cable connection

 - Microphone (MICPAT-D)  

E-VOL60