Instruction manual
ZONE4R
9
Installation instructions
You must assign the ZONE4R unit to a zone number by pushing knob ‘1’ and ‘3’
simultaneously during 5 seconds. The selected zone number is displayed on the
screen ‘2’. To change the zone number, push the up or down switches ‘5’ or ‘6’.
After a few seconds, the ZONE4R returns to normal operation and will memorize
its assigned zone automatically. You can also switch zones by pushing the small
switch at the back of the unit. With every push, the zone number changes 1 up,
from 1 to 4 and back to 1 and so on. You can connect multiple ZONE4R units to
the ZONE4 main unit using a straight through CAT5 cable hub. You can assign
multiple ZONE4R units to the same zone. The maximum number of ZONE4R units
connected to a single ZONE4 unit is 8 pieces. Maximum approved CAT5 cable
length is 100 meters per zone.