9
MICPAT-2 connection
MICPAT-6 connection
Priority levels
RJ45SPLIT
Paging switch connector: for selecting paging in zone 1 or zone 2 group. MIC1 will always override the
zone group preselection.
Paging group 1: connect GND to PG1 using a switch. Do not apply external voltages to these contacts.
Paging group 2: connect GND to PG2 using a switch. Do not apply external voltages to these contacts.
Note: MICPAT-2 is equipped with 2 switches for paging 2 zone groups and can be connected to the
euroblock connector.
The mic/line inputs all have different priority levels according to the table below:
MICPAT-6 must be connected to the PAGING INPUT 1 : connect the RJ45 plug to the selective paging
station RJ45 connector. The second wire, the one with the blank leads must be connected to the SGL in-
put euroblock : screen (black) to GND, blue to -, brown to +. The MIC1 level can be set using the controls
on the rear only. You can connect up to 5 pcs MICPAT-6 units to this input. Use one or more RJ45 split
units to connect the RJ45 connectors from the mics to the RJ45 connector. The SGL input of all
MICPAT-6’s must be connected in parallel on the SGL input euroblock.
MICPAT-2 (or other paging mic) can be connected to MIC/LINE 2 -4, depending on the priority level
required (see priority level table). Connect red wire to +, white wire to -, yellow wire to GND, black
wire to PG1, blue wire to PG2. You can preset the paging groups 1 and 2 using the dipswitches at the rear
of the MA246. The paging group settings are equal for mic 2 to 4.