8. INSTALLATION OF SOFTWARE 

The supplied CD-ROM contains "

SOFTWARE

" folder with a free software installation set for 

the sensor operation, identical as for AR40x base recorder (AR407 / AR406).  
The installation set includes the following applications: 

ARSOFT-CFG-WZ1

  - displaying current measurement data and battery voltage  

- configuration of parameters such as resolution, calibration of measurements,    
  ID numbers of sensor and retransmitter, input type and indication range for  
  analogue signals (AR433/434), options for alarms, display, access, etc. (chapter 10), the     
  software requires communication with the sensor via USB port 

ARSOFT-LOG-WZ3

  - graphic or text presentation of results recorded by AR40x with print-out option, input data   

  are downloaded each time from the text file with "csv" extension, created in the internal   
  memory logger, USB or SD/MMC card 

The latest

 versions of the aforementioned software are also available at the website (

www.apar.pl

 in section 

Download

). The detailed descriptions of the aforementioned applications can be found in the installation folders. 

 

9. ADDING AND REMOVING MEASUREMENT SENSORS FROM AR407/406 LIST 

By default, the sensor is supplied in "off" state (parameter ID=16, chapters 10 and 10.1). To display measurement 
data in AR40x base recorder, add the sensor to the measurement list. In a properly configured system, each sensor 
has its own unique identification number (

ID

 parameter). Before starting the procedure of adding the sensors, 

make sure that all devices in the configured system are running on the same radio channel number, which is 
different than the number of neighbouring radio networks (by default the channel number is 6, the higher 
numbers are preferred).

 The procedure of adding/removing sensors to/from the measurement list is 

described in the manual for AR40x recorder

 (for AR407 chapter 12.5, for AR406 chapter 11) 

 
NOTE:   

- sensors 

must 

 be indexed individually! 

- each sensor operating in the system 

must

 have a different ID number (

ID

 parameter)! 

For optimum system operation and in case of communication problems 

 (between sensors and AR40x base 

station) 

please refer to the operating notes in chapter 12.

 

 
 

10. SETTING THE CONFIGURATION PARAMETERS 

All sensor configuration parameters are contained in non-volatile (permanent) internal memory. 
AR434 sensor may display a failure error signal on the display, due to a lack of sensor or attaching a sensor other 
than the factory-programmed. In such a situation the proper sensor or analogue signal must be connected and 
the configuration must be programmed. 

Parameter configuration is done via USB port and ARSOFT-CFG-WZ1 computer software:  
 

- connect the device to a computer port and start and ARSOFT-CFG-WZ1 application 

 

- when the connection is made, the program window displays current measured values, voltage  

           of the battery and ID number of the sensor,

 

RX/TX

 LED indicates the presence of the transmission

 

 

- setting and viewing parameters of the device is possible in the parameter configuration window 

 

- new parameter values must be approved with the 

Submit changes

 button 

 

- the current configuration may be saved to a file or set with values read from a file 

 

- the sensor saves the configuration after disconnecting from the computer's USB

 (provided that  

           battery voltage is > 3.0V) 

 

Содержание AR431

Страница 1: ...yn ul Ga czy skiego 6 Tel 48 22 101 27 31 22 853 48 56 22 853 49 30 fax 48 22 101 27 33 Internet www apar pl email automatyka apar pl USER MANUAL AR431 AR432 AR435 AR436 AR433 AR434 WIRELESS SENSORS A...

Страница 2: ...T CONNECTOR IN AR433 434 7 7 CONNECTING TO A COMPUTER AND INSTALLATION OF DRIVERS 7 8 INSTALLATION OF SOFTWARE 8 9 ADDING AND REMOVING MEASUREMENT SENSORS FROM AR407 406 LIST 8 10 SETTING THE CONFIGUR...

Страница 3: ...mm spaced at 70x50mm available after removing the front cover or it may be hung using the top 2 holes at the rear of the housing To obtain IP65 the housing cover must be precisely tightened 2 GENERAL...

Страница 4: ...high long term stability of measurement accuracy and immunity to interferences compliance with RED directive 2014 53 UE protection against reverse battery insertion available accessories SMA antenna c...

Страница 5: ...sion path parameters 4 8 kbit s output power 5 dBm receiver sensitivity 106 dBm range open space 200m maximum 400m with retransmission function in buildings it depends on local conditions antenna SMA...

Страница 6: ...and c side view AR431 435 without LCD and LED alarm AR433 without LCD and LED alarm d AR437 1 USB connector for communicating with the computer is inside the housing e external measuring probes For t...

Страница 7: ...ecting sensors and measuring signals b connection of 2 and 3 wire transducers Iout current Uout output voltage 7 CONNECTING TO A COMPUTER AND INSTALLATION OF DRIVERS After you connect the device for t...

Страница 8: ...he same radio channel number which is different than the number of neighbouring radio networks by default the channel number is 6 the higher numbers are preferred The procedure of adding removing sens...

Страница 9: ...y on each device operating in the system sensors and AR407 AR406 recorder 6 3 ID 0 16 D number index 16 sensor off 16 4 RetrID 2 0 3 re transmitter number index 0 retransmission function disabled 0 No...

Страница 10: ...RTD sensors and 700 0 00 2 cjte temp of cold ends of thermocouples 20 70 0 C 0 automat automatic 0 C or constant compensation of temperature of the cold junction of thermocouples 0 C automat 3 dot po...

Страница 11: ...ible causes of the error exceeding the measuring range of the sensor from above sensor damage attached sensor is different than the one set in configuration chapter 10 3 parameter 1 inp ____ exceeding...

Страница 12: ...antenna cable from accessories to avoid obstacles such as walls ceilings furniture etc c 1 change disturbed radio channel in all system devices in each separately to another d 1 consider enabling ret...

Страница 13: ...cover and the back wall in its original position Fig 13 1 Disassembly of the rear wall Fig 13 2 Disassembly of the control board AR437 unscrew 4 screws in the front panel and remove them from the devi...

Страница 14: ...14 14 USER S NOTES...

Страница 15: ...15...

Страница 16: ...16...

Отзывы: