Installation: 

1. Connect and secure the power adapter.  The status indica-

tor will light green. 

2. Connect the SDI output to the receiving device via a coax 

cable.  If only one output is to be used, terminate the oth-
er with the included 75 ohm terminator. 

3. Use  the  internal  color  bar  test  signals  to  ensure  proper 

connectivity  between  the  DA-HDTV-SDI  and  the  receiving 
device.  Select  the  appropriate  test  signal  resolution  and 
rate using the Mode Switch positions 2 through 9. 

4. Set the rotary switch to position 0 (default). 
5. Connect a HDMI signal to one or the other input of the DA-

HDTV-SDI.    The  status  indicator  will  light  steady  amber 
when the unit has locked on to the input video signal.  (2 
to 10 seconds) 

6. 

If the input signal is a 1080p 50/59.94/60 signal (3G) and 
the  receiving  SDI  equipment  is  not  3G  capable,  set  the 
mode switch to position 1.  This will convert 1080p signals 
into 1080i signals.

 

 

Notes: 

 

This unit does not alter the incoming resolution or refresh 
rate.  Source and receiving equipment must be compatible.  
(i.e.:  if  the  source  outputs  60  Hz  and  the  receiving  SDI 
equipment  can  only  tolerate  59.94  Hz  signals  there  will 
exist an incompatibility.  The DA-HDTV-SDI is not responsi-
ble for this incompatibility.) 

 

The DA-HDTV-SDI has a factory  set, generic EDID on the 
HDMI input port.  If a different EDID is required by your 
source, then an EDID emulator should be installed. 

Accessories 

Power Adapter 

Stereo Phone Jack (1 x 2) 

75 Ω Terminator 

Mounting Screws 

Resolution 

Refresh Rates 

1920x1080p 

23.98 / 24 / 25 / 29.97 / 30 

50 / 59.94 / 60  Hz 

1920x1080i 

50 / 59.94 / 60  Hz 

1280x720p 

50 / 59.94 / 60  Hz 

1440x480i 

(NTSC) 

59.94 Hz 

1440x576i 

(PAL) 

50 Hz 

 

 

( Audio ) 

PCM 

Supported Formats 

Position 

Operating Mode 

Standard Operating Mode 

Interlacing Mode;  
converts 1080p to 1080i 

Position  Color Bar Test Pattern on SDI outputs 

1080p @ 50Hz 

1080p @ 59.94Hz 

1080i @ 50Hz 

1080i @ 59.94Hz 

720p @ 50Hz 

720p @ 59.94Hz 

576i (625i) @ 50Hz 

480i (525i) @ 59.94Hz 

Mode Switch Functions 

Note: SDI Color Bar test patterns do not include audio. 

Power
5 VDC

Mode

Switch

Audio

Monitoring

Output

SDI Video

Outputs

 

HDMI Video

Input

HDMI 

Loopout

CatX Input 

(HDMI)

Status 

Indicator

Scan

 

Status Indicator:  

Green indicates power, Amber 

indicates video input locked on. 

 

Scan button:  

Initiates scan of the two inputs for 

presence of video signal. 

 

CatX Input (HDMI):  

Allows for direct connection 

from Apantac Multiviewers and other products. 

 

Mode Switch:  

(see the Mode Switch tables) 

 

 

Audio Output:  

Analog audio head-phone jack.  

Monitors the first pair of audio channels. 