Keep a clean production environment and stay
away from static electricity
High Efficiency Static Removal
-400
-250
-125
01
25
250
400
900
750
600
450
300
150
0.3
0.8
1.3
1.9
2.4
2.9
3.4
3.9
4.4
5.0
5.5
6.0
6.5
Discharge Time(s)
-400
-250
-125
0
125
250
400
900
750
600
450
300
150
-5
-4
-3
-1
0
1
3
4
5
6
8
9
10
Ion Balance(V)
-400 -250 -125
Z
(
mm
)
450mm
900mm
600mm
750mm
400
0
125
X
(
mm
)
150mm
300mm
250
Discharge time distribution diagram of AP-DJ2813
Ion balance distribution diagram of AP-DJ2813
Test Length (mm)
Test Length (mm)
Note
:
The 0 point of the test length is the center position of the air blower
Test standard
:
ANSI/ESD.STM3.1
,
SJ/T 11446—2013
Test instrument: Trek charge plate tester
Test voltage
:
±1000V → ±100V attenuation
Test environment
:
humidity 50±5%
;
temperature 23±3
℃
Trek 150*150mm
charge plate tester
Test bearing chart of air blower
Test Height (mm)
Test Height (mm)